Installation Guide

AirSynergy Equipment Installation Guide
Page 51 Commercial in Confidence SYN-UG-007 Rev A0.41
Whether the system is required to be locked to a GPS timing reference.
A BSID is required for each AirSynergy. This should be in a format xxxxxx:xxxxxx where x
is a decimal digit.
Network configuration information for the SDR blade. This shall include the following
information for the front panel and the backplane.
o IP Address: Should only be set if Management IP Mode is set to Static IP Address.
See below for Management IP Mode parameter.
o Netmask: Should only be set if Management IP Mode is set to Static IP Address.
See below for Management IP Mode parameter.
o Default Gateway: Should only be set if Management IP Mode is set to Static IP
Address. See below for Management IP Mode parameter.
o Management VLAN: Specified as either Untagged or Tagged
o Management VLAN Tag: Should only be set if Management VLAN is set to Tagged
o Management IP Mode: Specified as Static IP Address or Obtain IP Address via
DHCP
o Ethernet Mode: Specified as Auto-negotiate or Fixed
o Ethernet Rate: Need only be configured if Ethernet Mode is set to Fixed, specified
as 10M or 100M.
o Ethernet Duplex: Need only be configured if Ethernet Mode is set to Fixed,
specified as Full or Half.
SNMP configuration information. This will allow events from the BS to arrive at the
specified Netspan server. This will include the following information:
o Read Only Community: This should be specified to the same value as in Netspan
Discovery Parameters (found under Server on Netspans left hand panel).
o Read Write Community: This should be specified to the same value as in Netspan
Discovery Parameters (found under "Server" on Netspans left hand panel).
o Community: Normally specified to the same value as for Read Only Community.