User Manual

AS4000 Central Terminal
Installation and Commissioning
DLP 009
605-0000-452
Issue 1.3dr Date 7/02/00
Page 1 of 10 © Copyright Airspan Communications Corporation 2000
SHELF CONTROLLER SOFTWARE DOWNLOADS
STEP PROCEDURE
1. Shelf Controller Software Downloads
The SC must be loaded with the latest Shelf Controller and TU software to ensure that the
cards operate correctly. All the software for the cards in the shelf is downloaded and stored
in the SC card. . All of the software versions are downloaded to the SC irrespective of
whether the SC is an AC SC or a CT SC. This is useful for fault finding
1. Before downloading the latest software it must be placed in the downloaddirectory
created in the root directory on the Sitespan PC when Sitespan was installed. The SC is
capable of storing two sets of configuration files
2. Connect Sitespan to the backplane modem shelf to be configured. Sitespan is connected
to P5 (labelled Sitespan 1)
SITESPAN 2 SITESPAN 1 E1IN
E1OUT
-48V FAN
Figure 30. Modem Shelf Backplane
3. The following procedure must be followed on Sitespan to download the software to the
SC card: Highlight shelf, click right mouse button and edit Shelf Properties.