1.5. Connect LAT Terminal
Connect LAT terminal to the terminal Port on the DACU
1 1
1
1
2
37
Shelf 4 Shelf 1
Shelf 3 Shelf 2
Terminal
OKFRU Fail
2. Forcing the DA Commissioning Unit to acquire a link
1. Ensure that the DTU has been set as in DLP-009 step 5.
2. The LKcommand forces the DACU to acquire a link as follows:
RW
Code
PN
Code
Up Link
Rate *
Down Link
Rate*
Overlay
code
Frequency channel number
within channel plan
LK 8 1 4 4 0 9
* The rate at which the link will acquire is defined as follows:
1: 10kbit/s
2 40kbit/s
3 80kbit/s
4: 160kbit/s
3. With the LAT connected to the DACU, ensure that it has booted-up, type:
TE 0 Puts DACU into test mode
W 426 Watch the link state
LK F 1 1 1 0 9 Acquire a downlink on TLAC (in this example RW 15, at 10kbit/s
channel 9)
LK 8 1 4 4 0 9 Acquire a downlink and uplink on TTC (in this example RW 8 at
160kbit/s channel 9
4. During these commands, the link status watchshould return the states as described in
paragraph 2. The final state should be 0B0B
5. The DACU now acquires, if the DACU fails to acquire it is faulty.
6. Measure and record output power.
3. Rx Sensitivity
1. Program the DACU to the correct frequency, PN code and ID number