User Manual

AS4000 Central Terminal
Installation and Commissioning
DLP 010
605-0000-452
Issue 1.3dr Date 7/02/00
Page 6 of 6
12. Check the output power of the DACU, and repeat step 11 until the output power
reaches +7.00dBm taking into account the cable loss.
13. Record the result.
14. Power off the DACU.
15. With the LAT connected to the DTU, restore the DTU from test mode by typing TE 1.
16. Disconnect the RF cables from the rack and connect the Antenna. The rack is now fully
commissioned.
4. Restoring shelf connections
1. Remove the test equipment and connecting cables.
2. Replace the Shelf covers and the protective cap on the coupler
3. Go to DLP-016.