GENERAL STATUS POLL AND SELF TESTS
The Shelf Controller can initiate general status polls to ensure that all the
information contained in the database is current. The general status poll is for
Fixed Assigned systems only. It is good practice to initiate a general status
poll before making any Sitespan measurements of the system. At power on
the Subscriber Terminal (ST) and AS4000 Central terminal (ACT) perform
self tests. The FRUs with self test facilities perform a self test and inform the
relevant [shelf] controller, which in turn passes the overall result of the self
test to the management system. The self tests can also be requested by the
management system from the Card View dialog boxes at any time the line is
not in use.
STEP PROCEDURE
Status Polls
1. Select Card View for the Shelf Controller (FA only) on the shelf to be polled (see
Selecting Views, GSI-017).
2. Initiate a general status poll by clicking the mouse on the General Status Poll
button.