OPERATING SITESPAN FOR FIXED ASSIGNMENT OVER
DEMAND ASSIGNMENT BACKHAUL
Use this procedure to provide a Sitespan connection to an Access Concentrator Site for a
Fixed Assignment Modem Shelf installed on the same site as a Demand Assignment CT
Rack
WARNING: When plugged into the modem shelf backplane, Sitespan becomes
the master controller and the shelf controller the slave. The
configuration file of Sitespan will automatically overwrite any
existing shelf controller configuration.
STEP PROCEDURE
DA Modem Shelf to FA Modem Shelf Interface Connections
The Sitespan 2 and SC AUX connectors are used to backhaul FA Modem Shelves.
To connect a FA Modem Shelf for backhaul to the AC Site provide a link cable
between the Sitespan 2 (9 way D-type) connector and the Sitespan 25 way D-type
connector on the FA Modem Shelf.
To connect a second FA Modem Shelf for backhaul to the AC Site provide a link
cable between the Sitespan Aux (9 way D-type) connector on the DA Modem Shelf
and the Sitespan 25 way D-type connector on the FA Modem Shelf.
SITESPAN
2
SITESPAN
1
E1OUT
-48V FAN AUX5 AUX9
SCAUX
SLOT 5 SLOT 9
E1IN
E1IN
E1OUT
SCLAT
E5
E5
Figure 12. Demand Assignment Modem Shelf Backplane