User Manual

AS4000 Wireless Local Loop
System Overview
GSI 003
605-0000-430
Issue 1.2 Date 7/4/99
Page 3 of 6
Mains Plug
CRU
~
PSU
NTU
NTU
Drop
Cable
Figure 20. AS4000 ST-V2 Connection
The maximum length of this Drop Cable is 25m. with a 40mm maximum bend radius.
1.4 Network Termination Unit (NTU) when using ST-V2
The two 2-wire VF line feeds connect to the CPE with the one or two NTUs located within
the customers premises into which a range of devices can be plugged.
In general, the customer has access to the same range of facilities that are supported by a
conventional copper pair. For normal telephony services, these could typically include:
multi-frequency or loop-disconnect dialling
subscriber private metering
intrusion tone
malicious call interception.
caller line identification
Note. Line reversal is not supported.
All tones, tone cadences and announcements which are generated by the Local Exchange
are passed transparently over the AS4000 System. Line feed voltage, ringing current and
ringing cadence are generated by the ST equipment.
The Customer Premises Equipment is connected to the NTU