User Manual

AS4000 Access Concentrator
Installation and Commissioning
DLP 004
605-0000-453
Issue 1.2dr Date 7/02/00
Page 2 of 4
2. Card Insertion
Insert the cards into the shelves, recording the serial numbers and revision status in the
test form. See DLP007. The actual cards provided will depend upon the customer
configuration.
a) The load Sharing PSUs go in slots 1&2.
b) The Shelf Controller goes in slot 3.
c) All other slot positions are configurable via Sitespan.
d) 3 CTUs are supported. Each CTU supports 4 CT modem shelves. Each CTU may
be cabled for four 120 E1s or four 75 E1s.
e) 8 XTUs are supported. Each XTU may be cabled for eight 120 E1s.
f) CU cards may go in any unused slot. (slots 15& 16 are preferred as they have no
E1 connections.
g) Slot 17 is available for card redundancy using a spare TU8 card, any other slot E1s
may be routed to this slot by relay operation.
Figure 13 and Figure 14 below show typical card installation for V5.1 and V5.2
applications.
PSU1
XTU
XTU
Spare
Spare
Sp TU8
PSU2
SC
CTU
CU
XTU
XTU
XTU
XTU
XTU
XTU
CU
Figure 13. Typical Card set for V5.1