Using the DMM check that the DC voltage supply across the input terminals (TB1(-);
TB2+;.for Supply 1 and TB4(-); TB5(+) for supply 2). Ensure that the voltage
measured complies with the site nominal voltage and is within the limits specified on
the test results sheet.
3. PSU Voltage AC Shelves: (Test 2a)
Using the DMM, measure and record the DC voltage at the front panel test points on
each of the PSUs on the Access Concentrator Shelf.
Card Fail
PSU OK
I/P A Fail
I/P B Fail
O/P Overload
O/P Underload
0V
2.1V
3.3V
5V
Figure 17. Access Concentrator Shelf PSU
Ensure that the voltages measured are within the limit shown in Table 7. Record the
results in test form.
Voltage Upper Limit Lower Limit
5V DC 5.25V 4.75V
3.3V DC 3.0V 3.3V
2.1V DC 2.1V 2V
Table 7. Access Concentrator Shelf PSU Voltages.
STOP. THIS PROCEDURE HAS BEEN COMPLETED.