User Manual

AS4000 Access Concentrator
Installation and Commissioning
DLP 008
605-0000-453
Issue 1.2dr Date 7/02/00
Page 3 of 4
8. Wait for the download to complete which could take several hours.
9. Once the software downloads are complete reset by hot pluggingthe Shelf Controller
Card
10. All the cards on the modem shelf now boot-up.
11. The TU cards l display the following LED sequence:
Note: The boot-up procedure for these cards takes approximately 15minutes.
a) Red LED, amber LEDs & green surface mount LEDs all ON. Green LED
FLASHING
b) Red LED ON, green LED FLASHING, amber LEDs OFF & green surface
mount LEDs showing download progress.
c) Green LED ON, green surface mount LEDs indicate card configuration as
shown below
LED DTU
1 Top OFF
2 OFF
3 ON
4 Bottom OFF
12. The rest of the cards displays the following LED sequence:
Note: The boot-up procedure for these cards takes a couple of minutes
a) Red LED ON & green LED FLASHING
b) Green LED ON
13. If the cards do not boot-up correctly, which is indicated if any of the cards display a
flashing red or continuous red LED only, follow the procedure in Appendix 3
14. Each card must be reset from Sitespan. Select card on shelf view double clickthe
card, or click right mouse button and select Airspan (card type) View