User Manual

AS4000 Release3 and Release 4 Central
Terminal Installation and Commissioning
DLP-003
605-0000-432
Issue 1.3a Date 18th October 1999
Page 2 of 6
1.2. Securing Rack Base
Using the base of the rack as a template, mark the floor locating positions through the
Cut-outs in the Rack Frame. Using a 13mm. diameter drill bit, drill four holes to a
depth of approximately 25mm. Position the CT rack over the four holes and screw the
four (supplied) M12 screws through washers to secure the rack base.
Rack Base
Washer
Fixing Screw
Figure 6. Securing Rack Base
Warning: These screws are provided as locating pins only and must be used
in conjunction with the overhead steelwork and not as an alternative method for
securing the rack.
Temporarily secure the rack to adjacent racks or steelwork until the overhead support
is in place.