2. To remove the cover release the ribbon from behind the retaining clip by firmly
gripping the ends of the clip front and pulling forward. When removed the
length of ribbon is sufficient to allow the cover to be placed on top of the
enclosure without the need to remove the connector itself.
3. Turn the retaining screws one quarter of a turn to release the cover. Slide the
cover to the left to disengage from the battery compartment, pivot out from the
bottom ensuring that the PCB components do not touch the Enclosure.
4. To replace the cover, reverse this process, ensuring that no cables are trapped
between the panel and the Enclosure.
5. Installing the AC power
1. Remove the battery cover compartment as described above
Base of Battery compartment
AC Cable
Inlet
AUX BATT Cable Inlet
(if required)
+
-
Front
2. Use a supply cord fitted with a mains plug in accordance with local requirements.
Terminate the wires on the AC input terminal block.
Function Colour
Live Red or Brown
Neutral Black or Blue
Earth Green or Green/ Yellow
3. Do not switch on the power until directed to at the commissioning stage.