User Manual

AS4000 Subscriber Terminal
Installation and Commissioning
DLP 010
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 1 of 6
SECTION 7:COMMISIONING
CONFIGURING SUBSCRIBER TERMINALS USING
STMON FOR WINDOWS
The following procedure will have to be completed before placing the AS4000
system into service.
The Service Interface Unit should be programmed prior to commissioning. All
results must be entered on the Commissioning Test Result Sheet, see DLP 015.
STEP PROCEDURE
1. System Turn-up
1. Ensure that the PSU is connected to the Service Interface Unit and that the PSU
is plugged into the AC Supply.
2. ST Programming Using STMON for Windows
1. For new STs configuration information is sent to the Service Interface Unit
instructing it as to which frequencies, PN, and in the case of Fixed Assignment
what RW code to use.
2. STMON is a windows based commissioning and monitoring program designed
for use with Demand Assignment Subscriber Terminals. It connects to the
Subscriber Terminal using a serial cable.
3. PC Interface
1. STMON for Windows communicates via the PC RS232 com port which
connects to the ST to Service Interface Unit. The PC interface cable is
terminated as in Figure 62.
Downlink Comms - Yellow or
Brown on White
Uplink Comms - Grey or White on Brown
Ground - Black or Blue on Red
Pin 1
Figure 62. STMON PC Connection