User Manual

AS4000 Subscriber Terminal
Installation and Commissioning
DLP 010
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 3 of 6
13. Setting Up STMON
1. If a security Dongle is needed connect the Dongle to the COM port. When the ST
leaves the factory it can be programmed using STMON for Windows without the
use of a dongle. If for security reasons it is decided to use a dongle to program the
ST then the dongle provided is attached to the parallel port of the PC/Laptop being
used. Once an ST has been programmed using a dongle it cannot be re-
programmed unless the dongle is attached to the PC. After use with a dongle the
ST can only be reset for use without a dongle by returning it to Airspan.
2. Select the STMON Set UP tab. Set the com port by clicking Change Port Number.
3. Click the mouse on the required Communications Port. If the com port required is
greater than Com 4 click Other and key in the required com port in the window
adjacent to the button.
4. Click OK to initiate the change