User Manual

AS4000 Subscriber Terminal
Installation and Commissioning
DLP 010
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 8 of 6
6. Enter PN code
7. If the ST is to be used in fixed assigned mode enter the RW code (2 digits)
8. Enter the identity (9 digits)
9. Enter check digit The algorithm check number is the sum of the RF, PN,
RW(FA only), and identity digits.
The number entered is the number in the units column of the result -1.
i.e. if the result of summing the digits was 14 the number entered would be 3
and if the result of summing the digits was 8 the number entered would be 7
10. Use * to end programming
11. Upon successful installation, the code acceptedtone is heard in the handset
receiver, consisting of 1400 Hz pulses for 1 sec on; 1 sec off, for 5 seconds.
For a failed installation, an incorrect codetone shall be heard in the handset
receiver, which consists of 1400 Hz pulses for less than 1 sec on, and less than
1 sec off, for 5 seconds. If the ST fails to accept the programming code after a
second attempt, confirm with the network planning staff that the correct code is
being used. Should the ST still fail to accept the code, the ST will need to be
replaced.
12. Power Cycle the SIU. The ST will reset and re-boot itself in accordance with
the programming code entered.