User Manual

AS4000 Subscriber Terminal
Installation and Commissioning
DLP 003
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 1 of 4
INSTALLING THE ANTENNA (POLE MOUNT).
Use this procedure to install the antenna. The mounting pole is not an Airspan
supplied item and the pole should be manufactured to suit local requirements.
Before installing the Antenna check that the proposed position meets the site
selection guidelines. See DLP 001
The Pole Mounting Kit comprises:
Item Quantity
Pole Bracket 1
M6 x 50mm Bolts 4
M6 Coiled Washer 4
M6 Plain Washer 4
Cable Tie 3
STEP PROCEDURE
1. Antenna Positioning and Securing.
1. Confirm the position of the Antenna ensuring that there is no obstruction in front and
to either side.
2. When multiple STs are deployed at the same site the recommended minimum
spacing between each Antenna is 1 metre.
3. The Antenna Mounting Pole should be fixed so that antenna panning can take place
in the horizontal plane and check that line of sight with CT antenna does not breach
the deployment rules. (see DLP 001). The Antenna Mounting Pole is locally
provided and should be 38mm or 1.5in diameter. The Pole should be fixed
according to the pole manufacturersinstructions.
4. Note: Leave adequate clearance around the Antenna assembly to allow for the full
adjustment range when aligning the Antenna.
5. Secure the Antenna Radium to the mounting pole using the pole bracket secured by
four M6*20mm Hex Head Set Screws, 6mm Flat, and 6mm Coiled washers as
shown in Figure 21. Tighten the Set Screws to a torque of 4Nm
6. Rotate the Antenna to face in the general direction of the CT. At this stage, only
tighten the pivot bolts sufficient to stop the antenna sliding down the pole.