M6 Coil
Washer
M6 Plain
Washer
M6 Set
Screw
Mounting
Pole
38mm
(1.5)
Figure 21. Antenna Pole-mount Positioning and Securing
2. Lightning Protection
1. When the antenna is attached to two / three floor dwellings lightning protection
should not be needed. If the Antenna is situated in an exposed position i.e on the top
of a multi-storey building the antenna should be grounded.
2. Run a 6mm stranded copper cable from the Antenna to a protection earth point i.e
building earth halo or earth provided specifically for lightning protection.
3. Secure the cable to the pole using straps and cleats as required
4. Fit a 6mm lug to the cable at the antenna end. Attach to the pole mount bracket
using the lower right M6 set screw as shown in Figure 22
5. Connect to the earth point in accordance with local practice.