User Manual

AS4000 Subscriber Terminal
Installation and Commissioning
DLP 004
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 3 of 4
Strain Relief Strap.
Ensure minimum bend radius
(100mm ) is not exceeded
Wrap Self Amalgamating
Tape over joint of mated Connector
Figure 24. Antenna and Drop Cable fixed to a Wall Mounting Bracket
2. Drop cable Termination (Type T6) at the SIU
1. Strip the Drop Cable using a knife or cable stripping tool to the dimensions shown in
Figure 25.
2. Place the connector over the cable end ensuring that the inner sleeve passes between
the inner core and screen braid
3. Crimp the connector using the Amphenol 531-CR596R Crimp tool.
6.4mm
(1/4)
6.4mm
(1/4)
12.7mm
(1/2)
7/16
HEX
Crimp here using Amphenol 531-CR596R Crimp Tool
Trim cable to these dimensions
Note: the inner sleeve passes
between the screen braid and
core insulator
F-Type Connector
Figure 25. Terminating F-Type Connectors to T6 cable