3. Drop cable Termination Type T10 at the SIU
1. Strip the Drop Cable using a knife or cable stripping tool to the dimensions shown in
Figure 26
2. Fold back the braid against the cable sheath.
3. Ensure that the centre conductor is clean of dielectric residue. Push the crimp pin over
the end of the centre conductor until the pin bottoms against the dielectric, then crimp
the pin to the centre conductor with the 0.96 Hex crimp on the Airspan 212-8000-058
Crimp tool.
4. Insert the cable into the connector ensuring the pin is through the hole of the insulator
at the bottom of the nut. Continue inserting the cable into the connector until it
bottoms out. Crimp the Connector with the 0.475 Hex crimp to retain the cable.
6.4mm
(1/4)
6. mm
(3/16)
7/16
HEX
Crimp pin here using 0.096Hex
crimp
Trim cable to these dimensions
CFS11U F-Type Connector
18.8mm
(11/16)
6.4mm
(1/4)
All Crimps made with Airspan 212-8000-058 Crimp Tool
Crimp body here using 0.475Hex
crimp
Note: the inner sleeve passes
between the screen braid and
core insulator
Figure 26. Terminating F-Type Connectors to T10 cable