User Manual

AS4000 Subscriber Terminal
Installation and Commissioning
DLP 007
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 3 of 4
4. Drill the four holes, 8mm. Diameter to a depth of 50mm. (use a depth gauge) and
then fit the FUB x 50mm Wall Plugs (Part No 128-0000-123) provided.
5. Secure the Wall Mounting Bracket squarely in position using the No 8 x 50mm
screws (Part No 174-0815-002) and cup washers (Part No 192-0080-230)
provided.
1.1 Connecting the Drop cable and PSU
1. Plug the F-Type connector into the F-Type connector on the Service Interface
Unit. Important Notice: Care should be taken when screwing the F-Type
connector into the connector on the rear plate of the Antenna to ensure that the
connector is not over-tightened as over-tightening will strip the thread. Use a
torque spanner set to 2.3Nm (20in lb).
2. Plug the PSU into the wall socket using the appropriate socket adapter and plug
the DC output into the Service Interface Unit.
12V DC
10101
2 1
Serial No
Manufacturers
Serial No
Part No
Minimum bend
radius 70mm
Drop Cable
12V DC PSU O/P
No8 x 50mm
Screw + Washer
Torque to
20 in lb
Telephone
Engineer Access
Figure 40. S Series Service Interface Unit (installed)