User Manual

AS4000 Subscriber Terminal
Installation and Commissioning
DLP 008
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 3 of 8
100mm
50mm
167mm
100mm
130mm
12.5mm
Figure 47. Service Interface Unit Positioning
4. Drill the 3 holes, 8mm. Diameter to a depth of 50mm. (use a depth gauge) and
then fit the FUB x 50mm Wall Plugs (Part No 128-0000-123) provided.
5. Secure the Wall Mounting Bracket squarely in position using the No 8 x 50mm
screws (Part No 174-0815-002) and cup washers (Part No 192-0080-230)
provided.
6. The bracket lugs fit into the mounting slots cut into the Service Interface Unit.
The interface connection panel should be at the bottom. Pull down to lock into
position. See Figure 35.
7. Plug the F-Type connector into the F-Type connector on the Service Interface
Unit. Important Notice: Care should be taken when screwing the F-Type
connector into the connector on the rear plate of the Antenna to ensure that the
connector is not over-tightened as over-tightening will strip the thread. Use a
torque spanner set to 2.3Nm (20in lb).
8. Plug the PSU into the wall socket using the appropriate socket adapter. And
plug the DC output into the Service Interface Unit.