User Manual

AS4000 Subscriber Terminal
Installation and Commissioning
DLP 008
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 6 of 8
Interconnection of EIA-530 and V35
To provide the interconnection of EIA-530 with V35 wire as shown in Figure 49.
Table 4 shows complete interconnection details and should be referred to for non-
standard applications.
1
14
13
2
3
7
25 Male
B A
F E
L K
R P
V U
Z Y
DD CC
JJ HH
NN MM
D C
J H
N M
T S
X W
BB AA
FF EE
LL KK
B A
F E
L K
R P
V U
Z Y
DD CC
JJ HH
NN MM
D C
J H
N M
T S
X W
BB AA
FF EE
LL KK
25
Figure 49. Interconnection of EIA-530 and V35
EIA 530 CCITT V35
Circuit, Name and Mnemonic Pin No Pin No Circuit, Name and Mnemonic
Shield 1 A Shield
Transmit Data BA (A) 2 P 103 (A) Transmit Data
BA (B) 14 S 103 (B)
Receive Data BB (A) 3 R 104 (A) Receive Data
BB (B) 16 T 104 (B)
Request to Send CA (A) 4 C 105 Request to Send
CA (B) 19
Clear to Send CB (B) 13 D 106 Clear to Send
CB (A) 5
DCE Ready CC 6 E 107 Data Set Ready
DTE Ready CD 20 H 108/1,/2 Data Terminal ready
F 109 Data Channel Receive Line Signal
Detect
Signal Common AB 7 B 102 Signal Common
Transmit Signal Element DB (A) 15 Y 114 (A) Transmit Signal
Timing (DCE Source) DB (B) 12 AA 114 (B) Element Timing
Receive Signal Element DD (A) 17 V 115 (A) Receive Signal
Timing (DTE Source) DD (B) 9 X 115 (B) Element Timing
Local Loopback LL 18 L 141 Local Loopback
Remote Loopback RL 21 N 140 Remote Loopback
Test Mode TM 25 NN 142 Test Indicator
Table 4. EIA530-V35 Connections