500mm
550
50mm
30mm
20mm
510
20mm
30mm
480mm
5. Using the Enclosure as a template, mark the first hole position. Where the
Enclosure is to be mounted to a brick built building, try to ensure that each hole
coincides with the middle of a brick and not the mortar course.
6. Drill the first hole, 10mm diameter to a depth of 75mm (use a drilling depth
gauge), place the Enclosure on the wall and then fit the Hex Head M8 x90mm
DynaBolt provided through the enclosure into the hole.
7. Using a spirit level, adjust the position of the enclosure and mark the remaining
three holes. Remove the enclosure and drill the remaining holes
8. Drill the remaining holes, 10mm diameter to a depth of 70mm, then fit the M8 x
90mm DynaBolt provided through the mounting bracket into the holes.
9. Tighten all the bolts sufficient to ensure a firm fixing to the wall.