User Manual

AS4000 Subscriber Terminal
Installation and Commissioning
DLP 009
605-0000-454
Draft Issue 1.3 Date 8/02/00
Page 5 of 18
3. Securing Enclosure to Floor
1. Disconnect the power management ribbon from the cover of Battery and PSU
compartment. Remove the cover. The cover is secured by two quarter turn
fasteners at the side of the lid above and below the fuse holders. Disconnect the
Molex connectors to the PCB and the earth connection to the cover. Place cover
in a safe place.
2. Separate the Plinth from the Enclosure by removing the four M8 bolts from the
front and rear of the Enclosure
3. Using the Plinth as a template, mark positions for the four fixing holes on the
floor. Allow sufficient clearance from the wall to allow for cables to pass behind
the enclosure.
310mm
550
25mm
500
25mm
50mm
200mm
50mm
40mm
Fixing
Holes
Figure 52 Base of Plinth
4. Drill the four holes, 10mm diameter to a depth of 35mm (use a drilling depth
gauge), place the Plinth over the holes and then fit the M8 x 40mm Dyna Bolt
through the Plinth into the hole. Tighten sufficiently to secure the plinth to the
floor.