Power Consumption - Supply and Current
AirHarmony4200DCInternalFilterssupportsdirectconnectiontoDCpowersource.
DCPowerSourcerequirementsare:
OperationalVoltageRange:‐40.5to‐57VDCMax,8AMax
Safetyapproved(certified)accordingtoIEC/EN/UL609501
TransientVoltage:+150V(ETR283)
Theuseofotherpowersourcesmayimpair
safety
ACpowerfeedisalsoavailable,usinganAC/DCpowerconverterofferedbyAirspan.
Note:FormoredetailsontheofferedAC/DCconverter(soldseparately),pleasecontactyour
nearestAirspansales representative.
Table3:PowerConsumption
Duplex
TxPower
atRF
Port
(dBm)
Power
Source
Nominal
Power
Consumption
(W)
MAXPower
Consumption
withPoE
(Instantaneous)
MAXCurrent
withPoE
(Instantaneous)
(A)
PoEMaximum
Power
Consumption
(W)
PowerSupply
Requirements
(W)
TDD 4x3940 DC 265 387 4.30 60 400
TDD 4x3637 DC 265 387 4.30 60 400