Installation Guide
AirHarmony‐4200DC(InternalFilters)InstallationGuide
UGD‐D01196 AirspanCommercialandInternalUse 34
Figure11:Through‐bolt&Mountingplate
MountingplateisinstalledandreadyforAirHarmony‐4200DCmounting.
MountingonaWall
Thefollowingimagesshowthewallmountassembly.
Caution:TakecaretoinstallthePole/Wallmountingplateinthecorrectorientation.
Verifythatthemountingpinsarefacingupwardsasshownbelow.
1. Positionmountingplateagainstthewallwithmountingpinsfacingup.Besureto
positionthewallmountingplatestraightwithlevelmountingtoensuretheunitsits
evenly.
2. Markthewallthroughtheholesonthewallmountattherequiredheight.
3. Attachthemountingplateto
thewallusingLagbolts(x8recommended).
Note:Lagbolts(x8)andnecessaryhardwarearenotsuppliedbyAirspanandarethe
responsibilityoftheinstalle r.Recommendedminimum5/16x4”dia.(8mmx100mm)
withappropriateplugsaccordingtofieldconditions.