User's Manual

AirHarmony-1000 Installation Guide
UGD-D01006 Airspan Commercial and Internal Use 41
6.2 Wiring AC Power Cable on the AC/DC Converter
Advice: It is good practice to label both ends of the cable to identify which AirHarmony-
1000 unit it is connected to.
Advice: It is good practice to leave a spare loop of cable (approximately 0.5m). This will
allow for easier wiring and will allow the cable to be re-terminated if necessary in the
future.
Note: This is a waterproof connection therefore the use of die-electric gels is not
required.
The power cable is available in various lengths as required.
Figure 37: Waterproof connector exploded view
1. Route and bring the unterminated end of the AC power cable to the location of the AC/DC
converter.
2. Strip back and remove the outer sheath to expose the inner brown, blue and green insulated
wires to a length of 3cm (1.18 in). Then strip back 6mm (0.24 in) of the inner core insulation.
Figure 38: AC power cable preparation
Figure 39: Waterproof connector separated
3. Thread the prepared cable end through the gland, washer, sealing ring and body of the
connector.
Figure 40: Connector on cable
4. Secure the prepared ends of the cable into the head part of the connector.