User's Manual

AirHarmony-1000 Installation Guide
UGD-D01006 Airspan Commercial and Internal Use 47
6.5.2 Tool Requirements
Table 15: Tools
Tool
Recommended (or equivalent)
Image (examples)
Wire Cutters/snips
Standard
CAT5e Jacket
Strippers
Fluke Networks UTP/STP Adjustable Cable Stripper
and Cutter Model # - 11230002
RJ45 Crimping
Tool
Fluke Networks Modular Crimper RJ45 - Model # -
11212530
Ethernet Cable
Tester
Standard
6.5.3 Assembly Instructions
In order to properly assemble the Ethernet cable follow the steps listed below:
1. Unroll the required length of Ethernet cable (CAT5e) and add a little extra wire, just in case.
2. Cut the required length of the cable.
3. Prior to stripping, pass the cable thru the tail nut, seal, body, front connector, and front seal
(self-stick) of the connector casing.
Figure 53: Ethernet cable thru connector
4. Peal and stick the front seal on the collar of the connector body.
5. Carefully strip the outer sheath insulation back 1- 2 inches using the Jacket strippers. Roll
back the foil shield insulation and the drain wire. Do not remove any insulation from the
conductors.