Hardware Installation Guide Installing the SPR
4.
5.
Adjust the vertical position of the SPR. Lock the SPR at the desired position by
inserting the locking bolt in the desired position. Once the correct angle has been
set both bolts must be tightened to lock the SPR bracket in place.
Adjust the horizontal position of the SPR by rotating the SPR about the pole, and
then tighten the U-bolt.
SPR positioning is obtained in two planes by adjustment of the mounting bracket
assembly a shown in Figure 10-11.
Rotation about the
mounting pole
Rotation about the
mounting bracket
Figure 10-11: SPR GPS orientation in vertical (top) and horizontal plane (lower)
Note: A thread-locking compound is to be used to prevent the bolts working
loose. A loop should be left in the cable for maintenance purposes and to
prevent the cable weight being taken directly on the connector.
02030311-07 Airspan Networks Inc. 10-13