Installation Manual

Hardware Installation Guide Installing the SPR
10.4. Connecting to the SDA
The SPR’s power supply and connectivity to the subscriber’s Ethernet network is
provided by the SDA. To connect the SPR to the SDA, you need to connect the
SPR’s 15-pin D-type port to the SDA’s 15-pin D-type port using a CAT-5 cable.
The SPR-to-SDA cable setup is as follows:
Cable: straight-through 10Base-T Ethernet UTP 4 Pair CAT-5e 24 AWG
outdoor type (100 meters)
Connectors:
SPR side: 15-pin D-type male (only 8 pins are used)
SDA side: 15-pin D-type male (only 8 pins are used)
Note: Airspan supplies unterminated CAT-5e cables. For a detailed
description on crimping cables, see Appendix B, “Cable Crimping".
Connector pinouts:
Table 10-4: SPR-to-SDA CAT 5 cable connector pinouts
Straight-through CAT-5 UTP PVC 4 Pair 24 AWG cables
SPR SDA 15-pin
D-type
male
Pin Function
Wire color Wire
pair
Pin Function
15-pin
D-type
male
1 +48 VDC Blue / White 1 +48 VDC
2 -48 VDC
Blue
1
2 -48 VDC
3
Tx+
Orange /
White
3
Rx+
4 Tx-
Orange
2
4 Rx-
5
Rx+
Green /
White
5
Tx+
6 Rx-
Green
3
6 Tx-
7
Sync.+
Brown /
White
4
7
Sync.+
02030311-07 Airspan Networks Inc. 10-21