User's Manual

02030311-10 Airspan Networks Inc. 14-1
Network Cabling
Network CablingNetwork Cabling
Network Cabling
This chapter describes the procedures for network cabling at the subscribe site, and
includes the following:
Connecting SPR to SDA
Connecting SDA to Subscriber's Ethernet Network
Connecting to a LAN/PC
Connecting to a Hub
Connecting to a Voice-over-IP (VoIP) Network (RGW)
Warning: To avoid electrical or fire hazard, ensure that the network
connections described in this chapter are made prior to connecting power.
14.1. Connecting SPR to SDA
SPR interfaces with the subscriber's Ethernet network through the SDA. To connect
the SPR to the SDA, you need to connect the SPR's 15-pin D-type port to the SDA's
Ethernet radio port (15-pin D-type for all SDAs except SDA-1 Type II, which
provides an RJ-45 port) using a standard CAT-5 cable.
The SPR-to-SDA cable setup is as follows:
Cable: straight-through 10BaseT Ethernet UTP 4 Pair CAT-5e 24 AWG
outdoor type (100 meters)
Connectors:
SPR side: 15-pin D-type male (only 6 pins are used)
SDA side: 15-pin D-type male (only 6 pins are used) for all SDAs except
SDA-1 Type II (RJ-45 port)
14