12.1 Troubleshooting
The table below provides some possible solutions to problems that may arise if the ProST is
incorrectly installed:
Table 17 - Troubleshooting
Problem Possible Cause Solution
No electricity at wall outlet Ensure household provides
electricity to the specific wall
outlet (professional electrician
required)
SDA-1 prongs not plugged
entirely into wall outlet socket
Ensure SDA-1 plug prongs are
completely inserted into wall
outlet
SDA-1 plug prongs attached
incorrectly to SDA-1
Remove the SDA-1 plug prongs
and reinsert them, ensuring the
following:
¾ Prongs are inserted into the
SDA-1's prong grooves
¾ Prongs slid to the end
¾ Switch is in LOCK position
SDA-1 (and therefore,
ProST) not receiving
power --POWER LED is
off
Network cables (radio and
LAN) inserted into incorrect
RJ-45 ports of the SDA-1
Ensure that the cables are
plugged into the correct SDA-1
ports:
¾ Port labeled RADIO: for
ProST-to-SDA-1
connectivity
¾ Port labeled LAN/PC: for
computer-to-SDA-1
connectivity
12.2 Glossary of Terms
BPSK
Binary Phase Shift Keying
BS
Base Station
BWA
Broadband Wireless Access
CID
Connection Identifier Number
CPE
Customer Premises Equipment (interchangeable with ST)
dB
Decibel
dBm
Power ratio in dB (decibel) of the measured power referenced to one
milliwatt
DL
Downlink
FDD
Frequency Division Duplex