Fujitsu General have been developing and manufacturing high quality and energy efficient products for more than 35 years. Using the latest Japanese technology and state of the art expertise, our products have been designed in accordance with our policy to “create the most comfortable environment” possible.
Our History ................................................. 4 High Quality Development & Production Environment ......................... 6 AIRSTAGE New Products ...................... 8 TM AIRSTAGE Line-up.................................. 10 TM • Indoor units range..................................... 12 AIRSTAGE Support ................................ 14 TM Design Support Tool ............................. 16 AIRSTAGE SOLUTION TM HIGH ENERGY EFFICIENCY ................. 20 MORE COMFORT ..........
FUJITSU GENERAL’s VRF AIRSTAGETM Series has been developed based on our long-term air-conditioning technology know-how and was first provided 10 years ago. We have offered a series of products from large homes to large-scale buildings to meet the various market needs. For Commercial Use For Residential & Light Commercial Use J series 6HP / Heat pump S series 10HP / Heat recovery & Heat pump Established as Yaou Shouten Ltd.
V-II series High efficiency and Compact design model Extensive lineup from 8HP to 48HP in 2HP increment / Heat pump New Product Initiatives Fujitsu introduced inverter technology which used R410A refrigerant.
The Headquarters-R&D Center (Japan) is equipped with a wide range of testing equipment envisioning a variety of operating conditions. This includes a testing tower with a 60m height difference for buildings. We provide high quality & reliable products that meet the customers' needs from all over the world through this advanced R&D Center and 6 factories based in China and Thailand. Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd. • Fujitsu General Limited Fujitsu General (Shanghai) Co., Ltd.
Advanced Research Facility and Equipment Performance testing Testing Laboratory Fujitsu General EMC Laboratory Limited Sound testing Air flow testing Calorimeter testing Transportation & Handling Vibration testing Reliability Testing Compressibility testing International Test Site for EMC Regulation 60m Height Difference Testing Tower Objective is to Confirm Oil Circulation of Compressor for Reliability Severe environmental Water shower testing testing 7
Small VRF system type • Small and light weight design • High seasonal energy efficiency • Effective air intake grill design • Adopting high performance twin rotary compressor • Lineup from 4HP to 6HP 8 NEW
User-friendly Wired Remote Controller • Easy finger touch operation with LCD panel • Backlight enable easy operation in a darkened room • Corresponds to 7 different languages Individual & Simple central control Wired Remote Controller (Touch Panel) UTY-RNRY Flesh air ventilation • 100% outdoor air intake possible • Compact size and high static pressure 200 Pa (22.
Fujitsu General provides multi air conditioning systems for buildings AIRSTAGE Series matched to the size and application of the property. Heat Recovery type for simultaneous heating and cooling operation Heat Pump type for heating or cooling operation • Systems compatible with individual operation mode control, as well as large offices, hotels, and large composite facilities • Extensive lineup from 8HP to 42HP increment connectable indoor unit capacity ratio up to 150%.
Heat Pump type for heating or cooling operation Heat Pump type for heating or cooling operation • Systems for large homes to medium sized offices, shops • Small capacity range from 4HP to 6HP connectable indoor unit capacity ratio up to 130% • Space saving design 3 models lineup • Systems for large homes to medium sized offices, shops • Small capacity range from 4HP to 6HP connectable indoor unit capacity ratio up to 130%.
Indoor units range Comprehensive range of indoor units of variety design and capacity ranges available which can be selected to suit any air conditioning needs. 12 types, 56 models, Capacity range from 2.2kW to 25.0kW Capacity range (kW) Model code 7 9 12 14 18 24 2.2 2.8 3.6 4.5 5.6 7.
30 34 36 45 54 60 72 90 9.0 10.0 11.2 12.5 14.0 18.0 22.4 25.0 AUXA34GALH AUXA36GALH AUXA45GALH AUXA54GALH ARXB30GALH ARXB36GALH ARXB45GALH ARXA30GALH ARXA36GALH ARXA45GALH ARXC36GATH ARXC45GATH ARXC60GATH* ARXC72GATH* ARXC90GATH* ABYA36GATH ABYA45GATH NEW AUXA30GALH ABYA30GATH ABYA54GATH ASYA30GACH *: ARXC60/72/90GATH cannot be connected to J-IIS series and J-II series.
Fujitsu General provides a variety of product and technical information to engineers and consultants and also conducts new product research and design support activities. We provide a wide range of support to maintain high quality from design to installation. Technical Information We provide information and tools that are useful for air conditioning system design, such as unit performance data and tools that make model selection and estimation easy.
Product information New product information is provided in the form of documents and movies for every new model released. These can be downloaded from a private section of our website. To access this website, please contact your Fujitsu representative. Features • Product News • Brochures & All Manuals • Feature Promotion Movie Training Fujitsu General has 7 training facilities around the world that regularly conduct specialized product, technical, and service training.
Design Simulator Put the charts and pens away and design your projects on your computer with ease using the Design Simulator. Everything from selecting indoor and outdoor units, allocating controls and optional parts to designing the piping and wiring systems is made easier using the program's built-in features.
Building Information Modeling (BIM) FUJITSU GENENRAL provides the Building Information Modeling (BIM) object models and contents for our VRF system and some products to the architect, designer and contractor using Autodesk® Revit® technology from our Website and Autodesk® Seek Website, etc. 3D and 2D product data We provide 3D data that closely resemble the actual product appearance. 2D CAD design operations are supported and 2D display is also provided.
Airstage VRF Systems can be designed to effectively provide an air conditioning solution from a large domestic residence through to a large scale commercial building.
Highly Energy Efficiency New model Previous model Efficiency is improved significantly by using DC twin rotary compressor, inverter technology, and large heat exchanger. 5 4 12%UP! 2.98 3.35 19%UP! 27%UP! 18%UP! 4.37 4.07 3.75 3.15 EER 8%UP! 3.7 3.2 3.2 3.45 COP 16%UP! 3.95 3.
Operation Performance is Effectively Controlled. Room temperature set point limitation (°C) 30 Heating Cooling 28 26 The minimum and maximum temperature ranges can be limited, which provide further energy saving while maintaining the comfort of the occupants.
Auto changeover function At Auto setting, the cooling/heating mode is automatically switched according to the set temperature and room temperature. Automatic cooling / heating operation for each ach room is possible 2°C 0.5°C Heating Set Temp. -0.5°C -2°C time Cooling operation Cooling fan operation Heating operation Heating fan operation Auto changeover setting allows for the product to easily switch between cooling and heating modes regardless of the operation mode of other indoor units.
Precision refrigerant flow control High Precise and smooth refrigerant flow control is achieved by using a DC Inverter control in conjunction with individual indoor unit electronic expansion valve control. This allows high precision comfortable temperature control of ±0.5°C. ±0.5ÛC Hot Hot Set temp. d Colld Low Thermal change of the room *Simulation in heating operation.
Outdoor unit rotational operation The compressor starting order is rotated so that the running time is shared. Rotation DC 1 DC 2 DC 3 DC 1 Rotation DC 2 DC 3 Rotation DC 1 DC 2 DC 3 Note: Rotational operation is alternated by the start / stop timing of the compressor.
Backup operation If one compressor fails, backup operation will be performed by the remaining compressors*. *: Note: Backup operation may not be possible depending on the trouble state. Advanced refrigerant control Innovative compressor control logic has been introduced in order to balance the refrigerant mass flow rate of each outdoor unit by controlling the inverter speed.
Overall piping length 1,000m Total pipe length 1,000 , m max. Height difference between outdoor and indoor units 50m max. Actual pipe length 165m* For the outdoor unit stated below : 40m max. (Outdoor temp. 5m max. (Outdoor temp. *: AIRSTAGE V-II series is up to 150m. -5°C) -5°C) Height difference between indoor and indoor units 15m max. Pipe length from first separation tube to the farthest indoor unit 60m max.
High capacity connection 4HP-6HP 8HP-42HP AIRSTAGE J-IIS series Heat Pump type TM AIRSTAGE VR-II series Heat Recovery type TM TM Connectable indoor unit capacity range Connectable indoor unit capacity range Connectable indoor unit capacity range 50 % to 130% 50 % to 150 % 50 % to 150 % Connectable indoor unit number up to 4HP-6HP AIRSTAGE V-II series Heat Pump type Connectable indoor unit number 8 up to 64 Connectable indoor unit number up to 48 AIRSTAGE J-II series Heat Pump type TM
Easily transported Easily craned using lifting belt hooks Design of outdoor unit allows for lifting straps to be used Transporting by forklift Transport with forklift is possible. Can be transported in a small elevator Easy access By adopting a L-Shape front panel that can be removed, the work space for installation and service has been significantly expanded by this new design. For multiple installations, work is performed easily and efficiently even in a narrow space.
Simple wiring work Installation of the wiring systems is made easier as the communication wiring can be installed continuously between the indoor, outdoor and RB units. or Parallel connection Easy evacuation - using vacuum mode function Serial connection Air Air The vacuum mode function enables all expansion valves of indoor units to be fully opened, making it easy to evacuate all the air inside pipe lines and indoor units.
Design for Easy Maintenance 7 segment LED is used to make it easy to check the details about the function setting status, refrigerant temperature, pressure, compressor operation time, and other factors for each model to make it easy to perform self-diagnostics. Movable PCB panel Easier for maintenance work behind the PCB Easy to read 7-segment LED : Confirm detailed operational and error status without using any specific equipment.
Continuous operation during maintenance Outdoor unit Non-stop operation When servicing a specific indoor unit, maintenance can be performed even without turning off the other indoor units. *Note: VR-II Series and J-II Series are not available. Indoor unit ON OFF ON Error diagnosis by Service Tool ON ON ON Service Tool UTY-ASGX Outdoor unit Necessary maintenance can be carried out after analysing the operation data. The service tool can be connected anywhere in the VRF network.
The AIRSTAGE series outdoor units were developed with structural designs and advanced inverter technology to provide higher efficiency. High durability technology has also been incorporated to ensure long-term use.
Smart and cutting edge design Extensive lineup from 8HP to 42HP in 2HP increment Connectable indoor unit capacity ratio up to 150% Simultaneous cooling and heating operation using 1 refrigerant system Cooling and heating can be freely selected for each indoor unit to provide simultaneous cooling and heating in rooms with large temperature differences. Annual cooling operation Use annual cooling operation for the rooms and other spaces that require constant temperature control throughout the year.
Features Efficiency in actual operation Top class high COP is achieved for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and our own technologies. (EER) 5 4 Space saving combination 3.65 3.35 3.34 10 12 3 2 8 3.65 3.47 3.08 14 16 18 3.35 3.34 20 22 3.18 3.19 3.08 24* 26 28 3.35 3.34 3.23 3.23 3.14 3.15 30 32 34 36 38 40 Space saving combination 42 (HP) For 24 HP Combination (EER ) 5 Energy efficiency 3.08 4 3.45 3.
Features All inverter compressor High efficient compressor speed control Comfortable space with small room temperature changes and little energy loss is created by 0.1Hz steps compressor speed control. Capacity Large capacity DC inverter compressor Large capacity high efficient DC twin rotary compressor with excellent intermediate capability. 0.1Hz Inverter frequency Multiple outdoor operation control When multiple outdoor units are connected a sophisticated operation is performed by each compressor.
Flexible piping connection A more flexible refrigerant piping work is possible by the use of various piping and RB Unit connections, for adjustments to the floor layout and building structure. Separation tube RB Unit (Single type) RB Unit (Multi type) Max.3 or 8 indoor units Application Max.
Outdoor units lineup • Combinations other than the followings are not recommended. Space saving combination 22.4kW (8HP) 28.0kW (10HP) 33.5kW (12HP) 40.0kW (14HP) AJTA72GALH AJTA90GALH AJT108GALH AJT126GALH UNIT : AJTA72GALH UNIT : AJTA90GALH UNIT : AJT108GALH UNIT : AJT126GALH 44.8kW (16HP) 50.4kW (18HP) 56.0kW (20HP) 61.5kW (22HP) AJT144GALH AJT162GALH AJT180GALH AJT198GALH UNIT : AJTA72/A72GALH UNIT : AJTA90/A72GALH UNIT : AJTA90/A90GALH UNIT : AJT108/A90GALH 68.0kW (24HP) 73.
Dimensions 8,10HP : AJTA72GALH / AJTA90GALH (Unit : mm) 690 (Bolt pitch) 530 (Bolt pitch) 8-12 × 17 (Hole) 732 (Bolt pitch) 80 930 B 1339 1576 1690 765 A C 12,14HP : AJT108GALH / AJT126GALH (Unit : mm) 1000 (Bolt pitch) 840 (Bolt pitch) 8-12×7 (Hole) 732 (Bolt pitch) 80 765 1690 1240 B Front side knockout position B Left side knockout position 73 43 Top view Ø 43.7 Pipe port Power supply cable port Ø 22.
Outdoor units specifications Space Saving Combination Rating Capacity range HP 8 10 12 14 16 18 20 Model name AJTA72GALH AJTA90GALH AJT108GALH AJT126GALH AJT144GALH AJT162GALH AJT180GALH Unit 1 Unit 2 Unit 3 AJTA72GALH AJTA90GALH AJT108GALH AJT126GALH AJTA72GALH AJTA72GALH AJTA90GALH AJTA72GALH AJTA90GALH AJTA90GALH 15 11.2-33.6 16 14.0-42.0 17 16.8-50.2 21 20.0-60.0 24 22.4-67.2 27 25.2-75.6 30 28.0-84.0 22.4 25.0 6.14 6.01 3.65 4.16 11,100 (3,084) 56 58 80 7.
22 24 26 28 30 32 34 36 38 40 42 AJT198GALH AJT216GALH AJT234GALH AJT252GALH AJT270GALH AJT288GALH AJT306GALH AJT324GALH AJT342GALH AJT360GALH AJT378GALH AJT108GALH AJTA90GALH AJT126GALH AJTA90GALH AJT126GALH AJT108GALH AJT126GALH AJT126GALH AJTA90GALH AJTA90GALH AJTA90GALH AJT108GALH AJTA90GALH AJTA90GALH AJT126GALH AJTA90GALH AJTA90GALH AJT126GALH AJT108GALH AJTA90GALH AJT126GALH AJT126GALH AJTA90GALH AJT126GALH AJT126GALH AJT108GALH AJT126GALH AJT126GALH AJT126GALH 32 30.
Smart and cutting edge design Extensive lineup from 8HP to 42HP in 2HP increment Connectable indoor unit capacity ratio up to 130% Excellent energy savings Heat pump type inverter control is used to achieve economic cooling and heating operation for individual air conditioning to entire air conditioning. High design flexibility for various building air conditioning The high static pressure design flexibly meets the needs of high rise buildings including easy installation on each floor.
Features Efficiency in actual operation Top class high EER is realized for all combinations by our unique heat exchanger structure, high efficient DC twin compressor, and other our own technologies. (COP) 5 4.37 4 Standard combination 4.37 4.02 3.93 10 14 4.17 4.08 3.97 3.93 20 22 24* 28 4.15 4.06 3.98 4.02 3.95 30 32 34 36 38 3.93 3 2 8 16 18 4.37 Energy efficiency 42 (HP) For 24 HP Combination (COP) 5 combination 4.02 4.23 4.
Outdoor units lineup • Combinations other than the followings are not recommended. Space Saving Combination 22.4kW (8HP) 28.0kW (10HP) 40.0kW (14HP) 50.4kW (18HP) AJYA72LALH AJYA90LALH AJY126LALH AJY144LALH AJY162LALH UNIT : AJYA72LALH UNIT : AJYA90LALH UNIT : AJY126LALH UNIT : AJYA72/A72LALH UNIT : AJYA90/A72LALH 55.9kW (20HP) 61.5kW (22HP) 67.0kW (24HP) 78.5kW (28HP) 85.
Dimensions 8,10HP : AJYA72LALH / AJYA90LALH (Unit : mm) 690 (Bolt pitch) 530 (Bolt pitch) 8-12 × 17 (Hole) 732 (Bolt pitch) 80 930 B 1339 1576 1690 765 A C 14HP : AJY126LALH (Unit : mm) 1000 (Bolt pitch) 840 (Bolt pitch) 8-12×7 (Hole) 732 (Bolt pitch) 80 765 1690 1240 B Front side knockout position B Left side knockout position 73 43 Top view Ø 43.7 Pipe port Power supply cable port Ø 22.2 Ø 50 Power supply cable port 75 Transmission cable port Pipe port Ø 22.
Outdoor units specifications Space Saving Combination Rating Capacity range HP 8 10 14 16 18 20 22 24 Model name AJYA72LALH AJYA90LALH AJY126LALH AJY144LALH AJY162LALH AJY180LALH AJY198LALH AJY216LALH Unit 1 AJYA72LALH AJYA90LALH AJY126LALH AJYA72LALH AJYA90LALH AJYA90LALH AJY126LALH AJY126LALH AJYA72LALH AJYA72LALH AJYA90LALH AJYA72LALH AJYA90LALH Unit 2 Unit 3 Maximum Connectable Indoor Unit*1 Indoor unit connectable capacity Cooling kW 15 16 21 30 32 32 33 36
Energy Efficiency Combination 28 30 32 34 36 38 42 24 26 28 AJY252LALH AJY270LALH AJY288LALH AJY306LALH AJY324LALH AJY342LALH AJY378LALH AJY126LALH AJY126LALH AJY126LALH AJY126LALH AJY126LALH AJY126LALH AJY126LALH AJYA72LALH AJYA90LALH AJYA90LALH AJY126LALH AJYA72LALH AJYA90LALH AJYA90LALH AJY126LALH AJY126LALH AJY126LALH AJYA72LALH AJYA72LALH AJYA90LALH AJYA72LALH AJYA72LALH AJYA90LALH AJYA72LALH AJYA90LALH AJY126LALH AJYA72LALH AJYA72LALH AJYA72LALH AJY216LALH
Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. Space saving and High seasonal efficiency Compact design and high seasonal efficiency are realized by ALL-DC technology, large capacity DC twin rotary compressor, and 3-row heat exchanger .
Features It Can be Easily Carried and Installed Obscure Place Small and light weight outdoor unit This model is much more compact than conventional 6HP comparable outdoor units. Even when installed on the balcony it fits within the height of the fence.
Features Long Piping Length Total pipe length 80m max. Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 80 m. This opens up new possibilities in system design. Actual piping length Height difference between outdoor and indoor units 50m max. 30m max. Piping length from first separation tube to the farthest indoor unit 40m max. Height difference between indoor and indoor units 15m max.
Specifications Rating capacity range HP Model name Maximum connectable indoor unit Power source Capacity Input power EER COP Airflow rate Sound Pressure level V / Ø / Hz Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW kW W/W Height Width Depth Weight Connection Pipe diameter Liquid Gas Total pipe length Max. Height difference Operation Range Heating 6 AJT054LCLAH 7 8 8 230/1/50 230/ 1 / 50 230/ 1 / 50 12.1 14.0 15.1 13.6 16.0 16.5 3.44 4.23 4.58 3.
Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses. High Energy Efficiency Heat pump inverter control is used to achieve an efficient cooling and heating operation in any indoor unit combination. Flexible systems for small- and medium-size buildings air conditioning Space saving design and long piping design allow for flexible installation on the roofs or balconies of smalland medium-size buildings.
Features High EER / COP 100 80 60 40 20 0 3 0 6 9 12 15 18 21 24 Time (h) High part load performance (6HP class) 4.53 4.00 Load curve (a typical office building) Building load (%) The building load is in the range of 40 % to 80%. Therefore, most air conditioners do not operate at maximum load, but operate at low to medium loads. Especially, for multi system, operation performance at partial load is important because air conditioners do not always operate at full load all the time.
Features Long Piping Length Total pipe length 180m max. Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design. Actual piping length Height difference between outdoor and indoor units 120m max. 30m max. Piping length from first separation tube to the farthest indoor unit Height difference between indoor and indoor units 15m max. 40m max.
Specifications Rating Capacity range HP 4 5 6 AJYA36LALH AJYA45LALH AJYA54LALH 6 8 9 Single-phase, ~230V, 50Hz Single-phase, ~230V, 50Hz Single-phase, ~230V, 50Hz Model name Maximum Connectable Indoor Unit Power source Cooling Capacity Heating Cooling Input power Heating EER Cooling COP Heating Air flow rate Cooling Sound pressure level Heating 11.2 14.0 15.5 12.5 16.0 18.0 2.80 3.89 4.49 2.76 3.81 4.56 4.00 3.60 3.45 4.53 4.20 3.
The AIRSTAGE indoor units were developed to be highly efficient, compact, low noise and to have user friendly operation. With a variety of indoor units and capacities available, Fujitsu have an indoor unit to match any requirement which is easy to install and maintain. Further, a variety of options are available to achieve an air conditioning environment that is more desirable from the user’s perspective.
Indoor units Models AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH Compact size panel design that fits standard ceiling panel (600x600mm) 2-stage turbo fan Quiet quality High efficiency design by 2 stage structure Optimization of wing form (laminar wing type) and wing number (7 blades each) An evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams.
Improvement of the airflow distribution High lift drain pump Ceiling panel Max. Max. 700mm 700mm 1 A B C D High ceiling mode 3 The compact cassette can be installed up to a height of 3.0m (12/14/18/24). 2 1 Grille cover Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily.
Indoor units Models AUXD18GALH AUXD24GALH AUXA30GALH AUXA34GALH AUXA36GALH AUXA45GALH AUXA54GALH NEW Powerful, wide airflow and quiet operation High efficiency turbo fan with 3-dimensional blade High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger. Previous turbo fan Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling.
Improvement of the airflow distribution High lift drain pump The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution. Front part Ceiling panel Max. 850mm Ceiling Bottom view High ceiling mode Rear part Much less temperature irregularity happens by spreading airflow widely Round louvre This cassette can be installed up to a height of 4.2m (36/45/54).
Indoor units Models ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH Small and compact indoor unit suitable for many applications Concealed Floor Low noise level Low static pressure mode Normal mode Airflow drop prevention Airflow A low noise level has been achieved for each capacity 7 Model Static pressure range Pa Noise level (Low speed) dB(A) 9 12 14 18 30 30 Low noise realized 0 to 50 27 24 25 Static pressure (Pa)
Compact design Flexible installation Ultra-slim duct air conditioner for easy installation Ceiling concealed Height 217mm Slim size (217mm) allows installation even where the space above the ceiling is narrow. Floor concealed Two-direction drain piping Filter (Accessory) ARXB07 / ARXB09 Filter (2pcs.) Duct indoor unit ARXB12 / ARXB14 / ARXB18 Filter (3pcs.) Two-direction drain piping Air-intake Air intake direction can be selected to match the installation site.
Indoor units Models (Drain pump internal model) ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH ARXD07GALH ARXD12GALH ARXD09GALH ARXD14GALH ARXD18GALH Slim design and wide range of static pressure for flexible installation. ARXD24GALH Slim Concealed Floor Slim design Air-intake With a slim indoor design, this indoor can be installed in narrow ceiling spaces. Air intake direction can be selected to match the installation site.
Auto Louver Grille Kit (Option) High lift drain pump Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior. Max. 850mm Slim Duct Auto Louver Grille Drain hose is standard accessory Selectable with a wide range of static pressure By using DC fan motor, it is possible to change of static pressure range 0 to 90Pa. The change of static pressure range is possible by remote controller.
Indoor units Models [ Low Static Pressure Duct ] ARXB24GALH ARXB30GALH ARXB36GALH ARXB45GALH Indoor units suitable for quiet rooms such as a hotel or a bedroom Models [ Medium Static Pressure Duct ] ARXA24GALH ARXA30GALH ARXA36GALH ARXA45GALH Slim Compact design allows for easy installation in narrow ceiling spaces up to 270mm Slim & Compact design 1,200 In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270mm, F
Line-up of low-noise and high-power models, compatible with a wide range of static pressure Easy maintenance See below for the case of rear suction type New model Previous model 1 Airflow 1 3 Duct type 4 1.Control box 2.Fan casing 4 3.Fan 4.
Indoor units Models ARXC36GATH ARXC45GATH ARXC60GATH ARXC72GATH ARXC90GATH These indoor units allow for high airflow quantities ARXC36GATH ARXC45GATH ARXC60GATH ARXC72GATH ARXC90GATH Specifications ARXC36GATH Model name ARXC45GATH ARXC60GATH Power source Capacity Cooling Heating Input power Airflow rate High Med 18.0 22.4 14.0 20.0 25.0 28.
Easy installation (Compact size & Lightweight) Static pressure selection Models : ARXC36 Models : ARXC72 / ARXC90 A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight. 2 Types of static pressure mode are selectable. 500 1,050 Volume Weight 47.5% 42% down down Max.
Indoor units Models ABYA12GATH ABYA14GATH ABYA18GATH ABYA24GATH The slim and lightweight design allow the unit to be suspended from the ceiling or installed on the floor. This type suits many room designs Floor standing Flexible installation Example for floor installation Example for ceiling installation Floor console Under ceiling Specifications ABYA12GATH Model name ABYA14GATH Power source Capacity Cooling Heating High Med Sound pressure level kW W Input power Airflow rate m 3/h (I/s) 3.
Super vane A combination of up/down and right/left directional swing allows three-dimensional air direction control. RIGHT and LEFT SWING 2 3 UP and DOWN SWING 1 4 1 Double Louvre Super vane with newly developed special configuration boosts airflow sending cool air quickly to every corner of the room. 5 2 Auto-closing louvre When operation is stopped, the louvres will automatically close. (This function is available on all non-ducted models.
Indoor units Models ABYA30GATH ABYA36GATH ABYA45GATH ABYA54GATH Easily concealed in any installation Installation Open Concealed Wall mounted (Field Supplied) General installation pattern which suspends the indoor unit from the ceiling. Installation pattern where part of the indoor unit is embedded into the ceiling. Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient.
Double auto swing and wide airflow High lift drain pump Auto airflow direction and auto swing Optional drain pump unit allows flexible installation design. Right and left Max. 500mm Fresh air intake 5 steps selectable Up and down Fresh air 1 Indoor Outdoor 2 3 4 High power DC fan motor 4 steps selectable • High power • Wide rotation range • High efficiency Long airflow Long Airflow ensures comfort to every corner of a large room.
Indoor units Models (EEV internal model) Models (EEV external model) ASYA07GACH ASYA09GACH ASYA12GACH ASYA14GACH ASYE07GACH ASYE09GACH ASYE12GACH ASYE14GACH Compact and Stylish design indoor Filter features High quality air conditioning by incorporation of high performance filter.
Auto swing louvre Compact size Powerful output even compact design Width 790mm Though the indoor unit is compact, it features a large, high pressure cross fan (90mm diameter) in a centre mounted configuration and a Lambda type heat exchanger to provide plenty of power. The Auto Swing Louvre function ensures that the air direction corresponds to the mode selected. 1 2 ing Sw 3 4 Step Swing 790mm Easy maintenance Easy maintenance has been realized as the front panel can removed for easy access.
Indoor units Models ASYA18GACH ASYA24GACH ASYA30GACH Simple & Elegant Appearance Design More comfort airflow by adopting power diffuser “Vertical airflow” provides powerful floor level heating “Horizontal airflow” does not blow cool air directly at the occupants in the room 5 5 (24/30) 2.5 2.
Air conditioner filter features Double auto swing A combination of up/down and right/left directional swing allows three-dimensional air direction control. 5 steps selectable Ion Deodorization Filter Organic coating fin used heat exchanger Apple-catechin Filter Air Filter 4 steps selectable High quality air conditioning by incorporation of high performance filter.
The AIRSTAGE control system can perform air conditioning control of individual room, centralized control by floor or by building, or centralized energy saving air conditioning control for large buildings. A variety of air conditioning management schemes are available to match the application, such as linking with the building control system, linking with a single split models, and using various interfaces.
Air Conditioning Individual Control For All AIRSTAGE series TM Wired Remote Controller (Touch panel) UTY-RNRY Wired Remote Controller UTY-RNKYT Simple Remote Controller UTY-RSKYT Simple Remote Controller UTY-RHKYT Without operation mode Wireless Remote Controller UTY-LNHY Service & Maintenance Tool Web Monitoring System Service Tool Software UTY-ASGX UTY-AMGX Monitoring Side VRF Network System Side Outdoor unit Internet or Public Telephone Line Transmission line Web Monitoring Tool USB Adapt
Air Conditioning Centralized Control System Controller Touch Panel Controller Software UTY-DTGY UTY-APGX UTY-ALGX (Lite edition) USB Adaptor *2 (Field supplied) Internet or Public Telephone Line Central Remote Controller UTY-DCGY Remote / Monitoring side Group Remote Controller UTY-CGGY Network Convertor UTY-VGGXZ1 Convertor / Adaptor (for external device) BACnet® Gateway BMS/BAS *1 Software UTY-ABGX USB Adaptor *2 (Field supplied) Network Convertor (BMS / LONWORKS®) UTY-VLGX External Swit
Max. transmission line length 3,600m • Wiring construction of the control system is made of power source wiring, transmission wiring and remote controller wiring. • Total wiring length (total length of transmission line) can be extended up to 3,600m (by using signal amplifiers). System Controller UTY-APGX Maximum 1,600 indoor units can be controlled.
Item Wired Remote Controller (Touch panel) Wired Remote Controller Simple Remote Controller Simple Remote *1 Controller Wireless Remote Controller UTY-RNRY UTY-RNKYT UTY-RSKYT UTY-RHKYT UTY-LNHY Model name Group Remote Controller Central Remote Controller Touch Panel Controller System Controller Lite Software Software UTY-CGGY UTY-DCGY UTY-DTGY UTY-ALGX UTY-APGX System Controller Max. controllable remote controller groups 1 1 1 1 1 8 100 400 400 1600 Max.
Individual Controller Max. controllable 16 indoor units UTY-RNRY Easy operation by high-definition large STN-LCD touch panel screen • Easy finger touch operation with LCD panel • Built-in weekly/Daily timer(ON/OFF,Temp.
Various convenient functions Displays setting status and Limitations • The remote controller settings can be easily checked Child lock • Lock / unlock method: Push the ON/OFF button and the screen (4 seconds) Summer Time display • This function can be set easily from Menu screen Name Registration • Indoor unit names can be registered in the remote controller screen. This makes it easy to identify the indoor unit you want to control in the room.
Individual Controller Max. controllable 16 indoor units UTY-RNKYT The room temperature can be controlled by detecting the temperature accurately from the built-in sensor • Simple operation with Built-in Weekly / Daily Timer. • Control up to 16 indoor units. • Up to 2 wired remote controllers can be connected to a single indoor unit. Functions Powerful features and compact size Built-in timers This Wired Remote Controller incorporates four primary functions into a single unit.
Max. controllable 16 indoor units UTY-RSKYT / UTY-RHKYT (Without Operation mode) Compact remote controller provides access to basic functions • Up to 16 indoor units can be controlled with one remote controller. • Suitable for hotels or offices as it is easily operated with no complex functions.
Individual Controller Max. controllable 16 indoor units UTY-LNHY Selectable Simple and sophisticated operations with a choice of 4 daily timers daily timers 4 • A single controller controls up to 16 indoor units. Functions Built-in daily timer Easy installation and operation Select from 4 different timer programs : On / Off / Program / Sleep Program timer : The program timer operates the ON and OFF timer once within a 24 hour period.
UTB-TWC Necessary to control for all duct type by Wireless Remote Controller • Up to 16 indoor units can be controlled with one remote controller. • Suitable for hotels or offices as it is easily operated with no complex functions.
Centralized Controller Max. controllable 8 remote controller groups UTY-CGGY Max. controllable 64 Group control of indoor units with simple operation group R.C. in a VRF network system • Up to 8 remote controller groups can be controlled by one Group Remote Controller. • Up to 64 Group Remote Controllers can be connected in one VRF network system. • Network Convertor (UTY-VGGXZ1) is required to connect Group Remote Controllers to a VRF network system.
Max. controllable 100 Indoor units UTY-DCGY Max. controllable 16 Central control of small- and medium-sized buildings and tenants. The operation status of all connected indoor units can be viewed at a glance on a large LCD monitor to simplify individual control to batched control.
Centralized Controller Max. controllable 400 Indoor units UTY-DTGY 16 High visibility and easy operation via high resolution 7.5 inch TFT-LCD touch panel screen • Large-sized 7.
Up to 400 indoor units can be controlled Group A Group B RB Unit It allows multiple indoor unit grouping Emergency stop control Air conditioner can be turned off through the external input control Emergency stop function Function Versatility • Up to 400 indoor units can be controlled • It allows multiple indoor units grouping • Schedule timer function is standard (20 patterns per day) • Emergency stop function(through the external input control) • Temperature upper and lower limit setting • The cloc
Centralized Controller Max. controllable 4 Software VRF network systems UTY-APGX Max. controllable 400 System Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large scale buildings. Outdoor units • Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units can be controlled.
Diverse operation management & Data management Standard for System Controller and System Controller Lite Schedule management Error display & E-mail notification • Annual schedules can be set for each remote controller group / user defined group. • Start / stop, operating mode, remote controller prohibition, and temperature settings can be set up to 143 times per day at 10 minute intervals for up to 101 configurations for each remote controller group.
Centralized Controller Remote management Standard for System Controller Option for System Controller Lite UTY-PLGXR1 System Controller may be used on site or remotely over various networks for remote central control. System Controller requires 2 softwares working together. VRF Controller runs on site and communicate with VRF system. VRF Explorer runs remotely and provides user interface and communicate with the VRF Controller.
FUNCTIONS SUMMARY System controller Function System specification Site supervision Error management History Operation control Schedule Remote managemment Electricity charge apportionment Energy saving management Others ż: Available. Type UTY-APGX Max. VRF networks supported Max. indoor unit / remote controller groups per VRF network Max. outdoor units per System controller Max. indoor units / remote controller groups per System controller Max.
Convertor / Adaptor Max. controllable 4 VRF network systems UTY-ABGX Max. controllable 400 Outdoor units • It is possible to connect medium to large sized BMS to VRF network system via BACnet®, a global standard for open networks. • A maximum of 1600 indoor units with 4 VRF network systems (a maximum of 400 indoor units & 100 outdoor units for one network system) can be connected to one BACnet® Gateway. • It is possible to control or monitor VRF network system from BMS via BACnet® Gateway.
Max. controllable 4 Units to BMS UTY-VLGX Max. controllable 100 Outdoor units Max. controllable • For connection between VRF network system and a LONWORKS® open network for management of small to medium-sized BMS and VRF network system. • The UTY-VLGX permits central monitoring and control of a VRF network system from a BMS through a LONWORKS® interface. • Up to 128 Indoor units can be connected to one Network Convertor for LONWORKS® 128 Indoor units Installation example Max.
Convertor / Adaptor UTY-TEKX Air conditioner switching can be controlled by connecting other sensor switches • In combination with a field supply Card-Key Switch or other sensor, the External Switch Controller allows control of the ON / OFF, Room temperature, Fan speed and Master control functions. This makes this product suitable for installations such as hotel rooms. • Card-key or other sensor switches are available as a field supplied parts.
Max. controllable 16 single indoor units UTY-VGGXZ1 Max. controllable 4 Group Remote Controllers • This Network Convertor is to be used for connecting single split system or Group Remote Controller (UTY-CGGY / UTY-CGGG) with the VRF network system. • Please select the function by switching the dip switch during the installation.
Service & Maintenance Tool Max. Monitor 100 Software Outdoor units UTY-ASGX Max. Monitor and control 400 Extensive monitoring and analysis functions for installation and maintenance. Indoor units • Operation status can be checked and analyzed to detect even the small abnormalities. • Data collected and stored on site can be checked later, off-line, off-site for more detail analysis. • One VRF network system with maximum number of up to 400 units can be monitored and controlled.
5) Error History 6) Remote File Download Displays the error information for each unit. The error information can sequentially be displayed up to 50 items as they occur starting with the latest error. Operation and error history data can be downloaded. Only the required data may be downloaded specifying the refrigerant system, unit and time range. 7) Commissioning Tool 8) Network Topology Analyzer * Test run commands can be executed with this tool.
Service & Maintenance Tool VRF network systems can be supported Software 4 UTY-AMGX Max. Monitor 400 Outdoor units Product features • Troubleshooting is performed by monitoring each unit remotely during periodical system checks off-site. • Operation status can be checked and analyzed to detect even the smallest abnormalities. • Four VRF network systems each with 400 units, with maximum number of up to 1,600 units can be monitored and controlled.
COMPARISON TABLE Item No.
High Efficiency and low noise levels are achieved by using a highly efficient heat exchange process. A comfortable air conditioned space is achieved by conveniently selecting whether to use heat exchange or normal ventilation setting, according to the requirements of the conditioned space.
Ventilation Models UTZ-BD025B UTZ-BD035B UTZ-BD050B UTZ-BD080B UTZ-BD100B UTZ-BD025B B UTZ-BD035B TZ BD035B UTZ-BD050B UTZ BD050 Energy recovery ventilator unit offers maximum comfort and greater energy savings. UTZ-BD080B UTZ-BD100B Heat exchange ventilation and normal ventilation Heat exchange ventilation When a room is cooled or heated, the exhausted cooling / heating energy is recovered by heat-exchange ventilation.
Energy efficiency and ecology Energy consumption is dramatically reduced by using a counterflow heat-exchange element. Air conditioning load is reduced by approximately 20%, resulting in significant energy savings. Recovers up to 77% of the heat in the outgoing air. Slim shape and easier installation 20% Counter-flow heat exchange element used for reduced noise and slimmer, more compact bodyy shape.
Ventilation Outdoor Air Unit Models ARXH054GTAH ARXH072GTAH ARXH096GTAH The heat pump method efficiently processes the outdoor air for cooling and heating and supplies 100% fresh air into a room. ARXH054GTAH ARXH072GTAH ARXH096GTAH One VRF system can provide air conditioning and air supply at the same time. Outdoor Air Unit can be connected in a same VRF*1 system as one of indoor unit series and can create fresh and comfortable air supply together from our high advanced technology.
High energy savings and flexible duct design by using DC motor Various Controller Supplied variety of controllers as options, such as individual controller, central controller, and building management controller. • Greatly reduces electricity consumption by adopting permanent magnet compared to when using an 054 / 072 type 096 type AC motor. • Compared with AC motor, changing the speed makes it possible to respond flexibly to the external static pressure from 50 Pa to 240 Pa.
Models UTD-GXSA-W UTD-GXSB-W UTD-GXSC-W Closed louver Opened louver Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior. Flexible Control Dimensions with indoor unit • Operation Auto Louver can be operated by synchronizing remote controller • W2 Fitting Flame of indoor unit.
Option Connection Units Separation Tube Gas Pipe Gas Pipe Gas Pipe Gas Pipe Liquid Pipe Liquid Pipe Liquid Pipe Liquid Pipe UTP-AX054A UTP-AX090A UTP-AX567A UTP-AX180A Suction Gas Pipe Suction Gas Pipe Suction Gas Pipe Discharge Gas Pipe Discharge Gas Pipe Discharge Gas Pipe Liquid Pipe Liquid Pipe Liquid Pipe UTP-BX090A UTP-BX567A UTP-BX180A Header Outdoor Unit Branch Kit Gas Pipe Gas Pipe Gas Pipe Liquid Pipe Liquid Pipe Liquid Pipe UTR-H0906L / UTR-H1806L Suction Gas Pip
Specifications Separation Tube Model name Total cooling capacity of indoor unit (kW) Model name UTP-AX054A (for J-IIS only) UTP-AX090A UTP-AX180A UTP-AX567A 19.6 or less 28.0 or less 28.1 to 56.0 56.1 or more UTP-BX090A (for VR-II) UTP-BX180A (for VR-II) UTP-BX567A (for VR-II) 28.0 or less 28.1 to 56.0 56.1 or more 3-6 Branches UTR-H0906L UTR-H1806L 3-8 Branches UTR-H0908L UTR-H1808L 28.0 or less 28.1 to 56.
Option Controllers For Individual Control Wired Remote Controller (Touch Panel ) Wired Remote Controller UTY-RNKYT Simple Remote Controller UTY-RSKYT With operation mode UTY-RNRY Simple Remote Controller UTY-RHKYT Wireless Remote Controller UTY-LNHY Without operation mode IR Receiver Unit UTB-TWC For All Duct type IR Receiver Unit UTY-LRHYB1 For Cassette type For Centralized Control Group Remote Controller UTY-CGGY System Controller Lite UTY-ALGX 116 Central Remote Controller UTY-DCGY Software
Convertors / Adaptors For External device BACnet ® Gateway UTY-ABGX Network Convertor Software DVD-ROM (Software) for LONWORKS® UTY-VLGX External Switch Controller UTY-TEKX Software Protection Key For System expansion Network Convertor UTY-VGGXZ1 Signal Amplifier UTY-VSGXZ1 Panels For Cassette type Cassette Grille UTG-UFYC-W Cassette Grille UTG-UGYA-W For Compact Cassette type For Cassette type 117
Option Others Communication system: External Connect Kit For Indoor unit UTY-XWZXZ7 UTY-XWZXZB For Outdoor unit UTY-XWZXZD UTY-XWZXZ6 UTY-XWZXZE UTY-XWZXZ9 UTY-XWZXZF UTY-XWZXZC For RB unit For Central Remote Controller For Touch Panel Controller UTY-XWZXZ6 UTY-XWZXZ7 UTY-XWZXZA UTY-XWZXZ8 UTY-XWZXZB UTY-XWZXZA Function list Controller Indoor unit Operation / Stop All On / All Off – Batch Stop – UTY-XWZXZD UTY-XWZXZB Emergency Stop UTY-XWZXZD UTY-XWZXZB Forced Thermostat off UTY-XWZXZ
For Duct type Flange (Round) UTD-RF204 Flange (Square) UTD-SF045T Remote Sensor Unit UTY-XSZX For Medium Static Pressure Duct type / Ceiling type For Medium Static Pressure Duct type For All Duct type New amenity space can be offered by installing the Remote sensor.
Reference There are many applications for Airstage VRF systems including such markets as education, healthcare,hospitality, utilities, office buildings, apartment buildings, condominiums, and restaurants. Note: VRF Heat Recovery system provides simultaneous Heating and Cooling. System operates both Heating mode and Cooling mode. Medical and Healthcare Facilities VRF gives each patient individual control of their room temperature.
Educational and Religious Facilities In a school, an investment in VRF is an investment in your community. VRF is more efficient than conventional systems, providing financial savings to the school for many years. Also, a quiet VRF system creates a much better learning environment for students. HEALTHIER FACILITY ZONING VRF systems can be integrated with fresh air systems to ensure that air quality meets the needs of the teachers and students.
Reference Multi-Tenant Dwellings VRF improves the quality of multi-tenant buildings while reducing tenant complaints. High quality VRF systems let owners save on energy costs and reduced maintenance costs. With VRF, each tenant has individual control over the temperature setting for the comfort of their home. QUALITY INDIVIDUAL COMFORT By delivering quiet, efficient heating and cooling, VRF improves the quality of multitenant buildings and reduces tenant complaints.
Office Buildings and Retail Spaces VRF provides a comfortable work environment for all employees. Zoning ensures that energy is only used to cool/heat occupied offices. Quiet indoor units and precise temperature control creates the most comfortable and productive work environment. QUIET Indoor units and outdoor units creates a pleasant work environment and reduces noise complaints. ZONING Save energy by heating and cooling occupied offices.
FUJITSU GENERAL (AUST.) PTY LIMITED ABN 55 001 229 554 A Subsidiary of FUJITSU GENERAL LIMITED www.fujitsugeneral.com.