Specifications

Height difference: Max 30m
Pipe length: Max 70m
Offices
The compact dimensions allow the outdoor unit to be
installed below a window.
Height 900
Width 900
Depth 370
Unit: mm
System that allows individual air conditioning of multiple rooms
Discreet installation The maximum piping length is 70m, and can cope
with a wide range of applications from homes to
offices.
Long piping length
All indoor units come with a wireless remote
controller.
All indoor units are supplied with a
remote controller
Large capacity connectable
Compact VRF System allows design flexib
Separation tube system
Piping connection examples
Separation tube + header system
Shops
Homes
6
Max 8
Indoor units
connectable
150%
Connectable
capacity
Separation tube
Separation tube Header
EV kit
EV kit
900mm
Flexible design Superior design flexibility allows individual air
conditioning of multiple rooms.
Note: IR receiver unit is available for duct type indoor unit.
23
Indoor unit Wall mounted type (Compact)
Models: AS7 / AS9 / AS12 / AS14
(Unit : mm) Indoor unit Wall mounted type
Models: AS18 / AS24 / AS30
(Unit : mm)
Indoor unit Duct type (Compact)
Models: AR7 / AR9 / AR12 / AR14 / AR18 / AR22
(Unit : mm)
( ) : AR7 / AR9
*Service accessibility must be allowed for when installing the product.
Please consult the installation manual for the necessary service access size.
Indoor unit Duct type
Models: AR25 / AR30 / AR36 / AR45
(Unit : mm)
Control box metal
Service hole
Reference B
Reference A
Vertical dimension
500 mm from 50 mm below
reference A
Horizontal dimension
600 mm from 300 mm from
the left from reference B
Refrigerant piping flare connection (Gas)
Refrigerant piping flare connection (Liquid)
Drain piping connection
(Drain hose : I.D. 12 O.D. 16.2-17 L 620
50
or more
50
or more
2300
or more
60 or more
1500 or more
Refrigerant piping flare connection (Gas)
Refrigerant piping flare connection (Liquid)
Drain piping connection
(Drain hose : I.D. 17 O.D. 24 L670)
60 or more
50
or more
50
or more
1500
to 2000
1500 or more
Refrigerant piping flare connection (Gas)
Refrigerant piping flare connection (Liquid)
Drain piping connection (Drain pipe : I.D. 35.7 O.D. 38.1)
Refrigerant piping flare connection (Gas)
Refrigerant piping flare connection (Liquid)
Drain piping connection (Drain pipe : I.D. 21.5 O.D. 26.0)
100
or more
300 or more
Service hole
Control box
Brackets
Brackets
Air flow outlet
Control box
886 [596]
850 [560]
390
166
576
20
24
47
85
584
577
194
146
75
65
344
920 [630]
600 [400]
94
34
10
210
152
868 [595]
18
22
171
205
82
75
138
138
264 264 264
2
25
1176
586 626
118 158
500
50
300
36
1099
1135
1211
600
270
241
221
173
700
568
498
45138
32
67
185
808
187
499
546
690
257
1120
235
593
691
721
315
*Service accessibility must be allowed for when installing the product.
Please consult the installation manual for the necessary service access size.
Variable Refrigerant Flow System
TM
Easier outdoor unit installation
Up to 8 indoor units can be connected to 1 out-
door unit. Furthermore, the indoor unit connection
capacity can be up to 150% of the outdoor unit
rating. This increases design flexibility.