Installation Guide for Model MV or MX Diffuser
www.airtecproducts.com Phone (800) 324-7832 Fax (508) 673-0115
Choose an area free of obstructions (joists,
electrical wires, etc.) for location of diffuser.
For 6,7,8 inch boot mark a 9-1/4” diameter
hole in the ceiling. For 4,5,6 inch boot
mark a 7-1/8” hole. Cut hole using
desired method (hand saw, utility knife,
1
Adjust volume damper for desired airflow with
a straight-blade screwdriver or insert included
handle through the access hole in the center
of the grille and snap firmly in place. Handle
may be removed or left in place.
Tighten four screws until the unit is firmly
secured in the ceiling. Clips will automatically
swing to proper position.
Push the diffuser and flexible duct into open-
ing until grille contacts the ceiling. Rotate unit
until it is paral
lel with walls in the room.
Pull band around perimeter of unit, unneed-
ed sections will break off to be recycled or
discarded.
The Model MV patented design will accom-
modate 3 different duct sizes. Be sure to
remove unneeded sections. Grasp tab
as
shown to initiate tearing action.
Pull flexible duct through hole.
Slide duct over a collar and secure using tie
wrap (provided). Tighten using tie wrap tool
or pliers
2
3
4
5 6
7
8
Use optional DCF Flange for added strength
in T-bar applications or RCF16 and RCF24
for new work at the rough in stage.
The buyer of the aforelisted product(s) hereby indemnify Airtec Products Corporation, its successors and assigns, as they may in time appear, harmless against
any claims, demands or liability arising out of the misuse of or from any use outside the intended scope of the aforelisted product(s). Misuse or use outside the
intended scope shall include any use contrary to that which is indicated with the accompanying literature and instructions. This unit must be installed in accordance
with all applicable local building and mechanical codes.
Airtec

Summary of content (1 pages)