User manual
1. Start on 
(1) Plug on, the unit gives off a sound like “di”. The “humidity ico” shows the current humidity. 
(2) Press ‘On/Off’ Both the ‘Dehumidify Ico’ and ‘Humidity Ico’ lights on, the ‘Humidity Ico’ 
display the previous set humidity, the initial setting humidity is 60% and 3 seconds later the 
‘Humidity Ico’ display current humidity. 
(3)  Press humidity up or down button to adjust the humidity if needed .If the setting humidity is 
3% less than current humidity, the unit runs; if the set humidity is 3%more than current 
humidity, the unit stops running. 
2. Shut off 
 Press ‘ON/OFF’ when the unit is running, all the indicators turn off but the “Humidity Ico” 
shows the current humidity, the unit stop running. 
3. Humidity accommodate 
(1) Press the humidity up or humidity down button with the’ Humidity Ico’blinking.3 
seconds after the humidity has been adjusted, the ’Humidity Ico’ lights on. The 
humidity accommodate is range from 30%to 90%, and it should begin in 60%. 
(2)  Press the humidity up or down button, the humidity will be rise or drop by 1%; keep 
pressing the keys, to rising or dropping the humidity by 5%. 
(3) Press humidity down button when the accommodated humidity is on 30%, to make it 
in dehumidify mode, the ‘Humidity Ico’ will show the current humidity after 3 seconds 
since the ‘Humidity Ico’ shows “CO”. 
4. Wind-speed control 
High speed mode and low speed mode can be switched in circulation by press the 
“fan button” each time. Pretermission is the high-speed mode. 
5. Time accommodate 
Press the “timer button” to set the time to shut off with the unit running. Press the same button 
to set the time to start on. There are three icos marked with “2h”.”4h” and”8h”on them, the time 
will be add 2hours by press the “timer button” each time, it can be range from 2 hours to 14 
hours which means the three ico all light on. Press the “timer button” when the time has been 
set on 14 hours to cancel timing. Press the “ON/OFF” button when the timing system has 
started to cancel timing. 
The unit will stop working on the time had been set to shut off,” timer ico” lights off. The unit will 
start working under previous mode on the time had been set with the “timer ico” lights off. Time 
indicators measuring (1means light on 0 means light off) 
2h ico 
1 0 1 0 1 0 1 0 
4h ico 
0 1 1 0 0 1 1 0 
8h ico 
0 0 0 1 1 1 1 0 
Time(hours) 
2 4 6 8 10 12 14 None 
6. Press the button both humidity up and down, the “humidity ico” shows the current 
humidity 3 seconds later. 
 4