5.2 eFemto Location for Installation
The following list defines the eFemto location requirements for deployment inside the
building:
Flat 24”x24” wall space so a physical clearance of 5” on all sides of the device is
observed to ensure efficient operation of the cooling fans and antennas
A building support beam for mounting support (recommended)
Access to a AC power source and breakers to accommodate up to 15 amps / 120
VAC (ceiling access is recommended)
Access to an Ethernet port to connect the enterprise LAN line to the internet
backbone (ceiling access is recommended)
Must be within 15 ft (5m) from a window that has no metal sheeting with a clear
view of the sky
Moderate temperature between 32°F and 122°F
Dry environment with relative humidity between 0 to 95% non-condensing
Equipment needed for installation:
Drill or screwdriver with medium Phillips head
Step ladder to install and connect the cables
3 screws size #10 pan head x 2” with washer to install mounting plate
3 wall anchors optional (if required for wall mounting)
>6ft(2m)
<15ft(5m)
GPSAntenna
Ethernet
connection
Power
connection
Figure 4 - Possible Mounting Location for an eFemto device