User's Manual

AW100 Series System Installation Manual
____________________________________________________________________________
_____________________________________________________________________________
AirWalk Proprietary and Confidential Page 32 of 54
6.2.2 FA Change Procedure
The AW-100 is consists of two different family of IP-RAN.
AW100- 1xRTT
The following menu driven commands permit local changes of the FA.
Step 1
At the prompt enter the following:
> pn3383
// this will take you to the menu screen similar to below:
================= PN 3383 ====================
1. Tx Test
2. Rx Test
3. ParameterSetup
4. Rf Gain Display
5. xcvrSetup
6. ampSetup
7. Normal Gain Display
8. MakeTestCall
9. callClear
10. Overhead Calibration Control
11. Test Phone Setup (678 4711709)
12. Handoff Test
13. Set RF Test
14. System Calibration
15. Display BTS Status
0. Exit
--------------------------------------------------
Select Number ===>
Step 2
Enter the following:
Select number => 5