Service manual
12-31
CONTROL SYSTEM
SM CINCO 1-A.1 GB
o Technician Test mode is exited after 60 minutes from entry.
o All the menus, except technician menus- Status, Technician Test and their sub menus, are automatically exited
to the main menu after 1 continuous minute out of any press.
o When Technician test cool or heat menu is selected, it will blink constantly until this menu is escaped.
o Pressing select and escape buttons together when in RST for more than 5 seconds will restore only the
parameters of the factory settings. Acknowledge for restored parameters will be indicated by blinking RST for 3
seconds.