Service manual
12-39
CONTROL SYSTEM
SM CINCO 1-A.1 GB
12.11.3.1 Model Depended Parameters:
12.11.3.1.1 Wall Mounted Models- WNG
Parameter name
Model
25 35 50 60 72
NLOAD limits as a function of selected indoor fan speed
MaxNLOADIF1C 40 40 45 50 30
MaxNLOADIF2C 53 53 62 85 44
MaxNLOADIF3C 127 127 127 127 105
MaxNLOADIF4C 127 127 127 127 127
MaxNLOADIF5C 127 127 127 127 127
Indoor Fan speed
IFVLOWC 750 750 850 900 900
IFLOWC 850 850 950 1000 1000
IFMEDC 950 950 1050 1100 1150
IFHIGHC 1050 1100 1200 1250 1350
IFTURBOC 1150 1200 1250 1300 1400
IFVLOWH 750 800 800 800 850
IFLOWH 850 900 900 950 1000
IFMEDH 950 1000 1100 1150 1200
IFHIGHH 1100 1150 1250 1250 1350
IFTURBOH 1200 1250 1300 1300 1400
12.11.3.1.2 Wall Mounted Models- Delta/ HAD
Parameter name
Model
22 25 35 50 60 72
NLOAD limits as a function of selected indoor fan speed
MaxNLOADIF1C 43 45 42 45 50 30
MaxNLOADIF2C 48 58 60 62 85 44
MaxNLOADIF3C 65 75 80 127 127 105
MaxNLOADIF4C 127 127 127 127 127 127
MaxNLOADIF5C 127 127 127 127 127 127
Indoor Fan speed
IFVLOWC 750 800 800 850 900 900
IFLOWC 850 900 900 950 1000 1000
IFMEDC 950 1050 1000 1050 1100 1150
IFHIGHC 1100 1200 1200 1200 1250 1350
IFTURBOC 1200 1250 1250 1250 1300 1400
IFVLOWH 850 850 900 800 800 850
IFLOWH 950 950 1000 900 950 1000
IFMEDH 1050 1050 1100 1100 1150 1200
IFHIGHH 1150 1250 1250 1250 1250 1350
IFTURBOH 1250 1300 1300 1300 1300 1400