Service manual
5-37
PERFORMANCE DATA & PRESSURE CURVES
SM HADDCI 1-A.2 GB
5.9.8 Model: HAD022 / GC 22
5.9.8.1 Cooling
500
600
700
800
900
1000
1100
1200
1300
1400
10 15 20 25 30 35 40 45
Outdoor DB Temperature
Suction Pressure [kPa]
22/15
24/17
27/19
29/21
32/23
Indoor DB/WB
Temp.
1000
1250
1500
1750
2000
2250
2500
2750
3000
3250
3500
3750
4000
4250
10 15 20 25 30 35 40 45
Outdoor DB Temperature
Discharge Pressure [kPa]
22/15
24/17
27/19
29/21
32/23
Indoor DB/WB
Temp.