Service manual

2-2
PRODUCT DATA SHEET
SM HADDCI 1-A.2 GB
2.2 HAD009 / GC 9 WDI DCI
Model Indoor Unit
HAD009
Model Outdoor Unit
GC 9 WDI DCI
Installation Method of Pipe Flared
Characteristics Units Cooling Heating
Capacity
(1)
Btu/hr 8530(4440-10240) 8530(4432-11270)
kW 2.5(1.1-3.1) 2.5(1.3-3.6)
Power input
(1)
kW 0.73 0.69
EER (Cooling) or COP(Heating)
(1)
W/W 3.41 3.61
Energy efficiency class A A
Power supply V/Ph/Hz 220-240 / 1 / 50
Rated current A 3.2 3.1
Starting current A 10.5
Circuit breaker rating A 10
INDOOR
Fan type & quantity Crossflow x 1
Fan speeds H/M/L RPM 1150/950/800
Air flow
(2)
H/M/L m3/hr 420/350/270
External static pressure Min-Max Pa 0
Sound power level
(3)
H/M/L dB(A) 52/48/45
Sound pressure level
(4)
H/M/L dB(A) 39/35/29
Moisture removal l/hr 1
Condenstate drain tube I.D mm 16
Dimensions WxHxD mm 680 x250 X188
Weight kg 7
Package dimensions WxHxD mm 740x320x265
Packaged weight kg 10
Units per pallet units 36 units per pallet
Stacking height units 9 levels
OUTDOOR
Refrigerant control EEV
Compressor type,model Rotary, Panasonic 5RS092XDJ01
Fan type & quantity Propeller(direct) x 1
Fan speeds H/L RPM 760
Air flow H/L m3/hr 1390
Sound power level H/L dB(A) 64
Sound pressure level
(4)
H/L dB(A) 54
Dimensions WxHxD mm 760x245x545
Weight kg 36
Package dimensions WxHxD mm 880x310x610
Packaged weight kg 39
Units per pallet Units 12 units per pallet
Stacking height units 3 levels
Refrigerant type R410A
Refrigerant chargless distance kg/m 0.85kg/7.5m
Additional charge per 1 meter g/m No need
Connections between units
Liquid line In.(mm) 1/4"(6.35)
Suction line In.(mm) 3/8"(9.53)
Max.tubing
length
m. Max.15
Max.height
difference
m. Max.10
Operation control type Remote control
Heating elements kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
CONTENTS