INSTALLATION INSTRUCTIONS
FOR DCI SPLIT WALL MOUNTED AIR CONDITIONER
LOCATION OF OUTDOOR UNIT
Select the location considering the following:
OUTDOOR UNIT
1. The location must allow easy servicing and provide
good air circulation .
2. The unit may be suspended from a wall by a bracket
(Optional) or located in a free standing position on the
floor (preferably slightly elevated).
3. If the unit is suspended, ensure that the bracket is
firmly connected and the wall is strong enough to
withstand vibrations.
4. Unit location should not disturb neighbors with noise or
exhaust air stream.
5. Place the mounting pads under the unit legs.
6. Refer to
7. When the unit is installed on a wall, install the drain
connector hose and drain plug as shown in .
as shown in fig 4
figure 3 for allowed installation distances.
fig 1 and fig 2
Fig.1
1.Bottom of outdoor unit
2.Drain connector
Fig.2
Drain installation
Example
Fig 2
Fig 1
1
2
1
Fig 3
NOTES:
L1+ L2 30m and L1, L2 25m
H5m
H1 , H2 10m
No additional charge is required.
To indoor
unit2
To indoor
unit1
100 mm
nmi
100 mm
nmi
500 mm
nmi
400 mm
nmi
100 mm
nmi
Fig.4
1. Mounting pads ( 4)
Fig 4