Operation Manual

1. Remove the power supply cable that is
connected to the indoor unit!
2. To connect the indoor units to the outdoor unit,
use the following electrical cables.
3.
4. Connect the cable ends to the terminals of the
indoor and outdoor units, as shown in
fig7.Please select corresponding connection
according to the different indoor units.
5. Secure the multiple wire power cable with the
cable clamps.
Prepare the cable ends for the power input and
for the cables between outdoor and indoor
units as shown in figure 6a and 6b respectively.
ELECTRICAL CONNECTION BETWEEN AND UNITOUTDOOR INDOOR
Fig.5
1. Terminal
2. Cable clamp
NOTES:
The wire color code can be selected by the
installer.
ELECTRICAL REQUIREMENTS
Electrical wiring and connections should be made
by qualified electricians and in accordance with
local electrical codes and regulation. The air
conditioner units must be grounded.
The air conditioner units must be connected to an
adequate power outlet from a separate branch
circuit protected by a time delay circuit breaker, as
specified on unit's nameplate.
Voltage should not vary beyond 10% of the rated
voltage.
Fig7
Fig6a
100
40
8
8
BA
Unit A
Unit B
Unit C
Unit D
2
Fig6b
100
40
8
8
BA
Ú
Unit A
Unit B Unit D
QUATTRO UNIT
TRIO UNIT
Fig.7
1. Indoor unit terminal for WNG.
2. Cable clamp.
3. Indoor Unit terminal for
K, LS, PXD.
4. Power input cable.
5. Outdoor unit connection cable.
6. Power cable in the indoor side
to remove.
NL
1
2
Fig5