Solutions Guide THE SMART AIR CONDITIONING
Set the office at 72ºF Compatible with Amazon Alexa e Google Assistant
SOLUTIONS GUIDE Index 02 03 Airzone Integrated Zoning Systems Zoning Systems What is an Airzone Integrated Zoning System? What is Airzone VAF? 04 06 Algorithms and Integration Commercial Applications · Q-Adapt · Eco-Adapt · BMS Integration · VRF ducted units · VRF ducted and ductless units 10 Single-family Applications · Single-family 1
SOLUTIONS GUIDE Airzone Integrated Zoning Systems What is an Airzone Integrated Zoning System? Traditional Ducted HVAC The operation of a traditional ducted HVAC system is based on the control of several rooms as one single zone, maintaining its temperature in a comfort range. Nevertheless, this type of system may present several disadvantages such as: • It is not possible to control the energy supply for each zone individually.
SOLUTIONS GUIDE Zoning Systems The Integrated Zoning System developed by Airzone regulates the air flow supplied to each air-conditioned zone, and may satisfy the thermal needs of each one of them. In addition, it includes several efficiency algorithms which by controlling Inverter heat pumps (operation mode, set point temperature, fan speed, etc.) optimizes energy use.
SOLUTIONS GUIDE Algorithms and Integration Q-Adapt Q-Adapt is an algorithm that automatically selects the fan speed of the zoned indoor units depending on the number of zones calling for demand. This algorithm adapts the control system to the application of the installations and the air flow demand of each zone. This adaptation is carried out by assigning a weight (percentage) to each zone of the installation, which is mainly suitable for complex ducted installations with numerous zones.
SOLUTIONS GUIDE BMS Integration The Airzone Cloud HUB Webserver module provides Cloud connectivity and BMS/IT integration to the Airzone systems. Stay always in control of your HVAC systems anytime, anywhere. • Controls up to 32 Airzone systems. • Ethernet port for access to Airzone Cloud and BACnet IP. • RS845 port for BACnet MS/TP and Modbus. • Wi-Fi 2.4 GHz/5 GHz connectivity for Airzone Cloud access. • Bluetooth Low Energy (BLE) connectivity for Airzone systems configuration.
SOLUTIONS GUIDE Commercial Applications Case study Within the commercial sector, VRF technology can provide the most efficient solution, featuring a single cassette or split as indoor unit for each zone in a building.
SOLUTIONS GUIDE By implementing a combination of ducted indoor units and Airzone VAF into a VRF Installation, all these challenges could be overcome as illustrated in this example. 15% reduction in installed thermal power 49.5% reduction in pipes length 27.
SOLUTIONS GUIDE Commercial Applications VRF Ducted Units ZONE AREA (FT2) REQUIRED CAPACITY (BTUH) I.U. MODEL ST. SOLUTION REQUIRED CAPACITY (BTUH) I.U. MODEL AZ SOLUTION INSTALLED CAPACITY (BTUH) XXX-48 48000 Office 1 164.2 6,252.1 XXX-08 8,000.0 Office 2 184.6 7,025.9 XXX-08 8,000.0 Office 3 216.7 8,250.2 XXX-08 8,000.0 Office 4 156.9 5,973.7 XXX-08 8,000.0 Office 5 194.9 7,419.0 XXX-08 8,000.0 Office 6 175.7 6,690.2 XXX-08 8,000.0 Office 7 246.0 9,363.
SOLUTIONS GUIDE VRF Ducted and Ductless Units ZONE AREA (FT2) REQUIREd CAPACITY (BTUH) I.U. MODEL ST. SOLUTION REQUIRED CAPACITY (BTUH) I.U. MODEL AZ SOLUTION INSTALLED CAPACITY (BTUH) XXX-48 48000 8,000 Office 1 164.2 6,252.1 XXX-08 8,000.0 Office 2 184.6 7,025.9 XXX-08 8,000.0 Office 3 216.7 8,250.2 XXX-08 8,000.0 Office 4 156.9 5,973.7 XXX-08 8,000.0 Office 5 194.9 7,419.0 XXX-08 8,000.0 Office 6 175.7 6,690.2 XXX-08 8,000.0 Office 7 246.0 9,363.
SOLUTIONS GUIDE Single-family Application Single-family · DX + Zonesupplemental heat HVAC systems in single-family buildings are usually a combination of air conditioning and zone-supplemental heat elements. The following system is composed of an Inverter air conditioning ducted indoor unit (with a capacity of 45,000 BTUh) and floor radiant elements produced by a boiler. Four rooms will be equipped with air conditioning and radiant heating and one room (Restroom) only with radiant heating.
SOLUTIONS GUIDE ZONE AREA (FT2) THERMAL LOAD (BTUH) INDOOR UNIT MODEL AIRFLOW (CFM) AZ MOTORIZED DAMPER MODEL Living Room 645.9 24,546.4 797.9 2x10'' Bureau 280.8 10,671.7 346.9 8'' Kitchen 140.3 5,331.7 Hall 133.4 5,070.1 Restroom 78.7 2,994.0 XXX-42 173.3 6'' 164.
SOLUTIONS GUIDE Single-family Application Single-familiy · DX + Zonesupplemental heat + Auxiliary heat Oftentimes, the combination of Inverter air conditioning and zone-supplemental heat does not provide enough coverage to meet the thermal load. In these cases, HVAC installations are complemented by auxiliary heating elements such as a electrical furnaces. Airzone VAF allows for control of the On/Off operation of these auxiliary elements via dedicated relays placed on the VAF main controller.
SOLUTIONS GUIDE ZONE THERMAL LOAD (BTUH) AREA (FT2) INDOOR UNIT MODEL AIRFLOW (CFM) AZ MOTORIZED DAMPER MODEL 264.1 6'' XXX-42 264.0 6'' Bedroom 1 202.6 7,699.1 Bedroom 2 202.5 7,695.0 Bedroom 3 163.9 6,231.2 213.8 6'' Restroom 1 166,7 6,335.3 - - - Restroom 2 166.7 6,335.
Designed & Manufactured in EU AIRZONE NORTH AMERICA CORPORATION 1800 SW 1 ST Avenue. Miami, FL 33129 airzonecontrol.