User's Manual

KDC User Manual
90
Revision 3.05.R6
Copyright ® 2014, KoamTac, Inc.
9.2.5 Resolution of Inconsistencies
Three types of inconsistencies could arise in the assignment of symbology options. The
decoder has pre-defined strategies to resolve these inconsistencies: If UPCE_as_EAN13
is true, then UPCE_as_UPCA is ignored.
If symbology conversion is selected but the target symbology is not enabled, then the
decoder still outputs the symbol in the target symbology. For example, suppose UPC-E
is enabled and UPCE_as_EAN13 is true but EAN-13 is disabled. All UPC-E symbols will
be shown as EAN-13 and EAN-13 options (if specified) will be applied. For the two
symbologies that have optional check digits, Code39 and Interleave 2 of 5, the decoder
will always transmit the check digit if the verification is disabled.
Verify Check
Digit
Return Check
Digit
Description
Disabled
Enabled or Disabled
Check digit is not verified but is transmitted
Enabled
Disabled
Check digit is verified but is not transmitted
Enabled
Enabled
Check digit is verified and is transmitted
Table 11 - Resolution of Inconsistencies