User's Manual

KDC User YOUR KDC
77
Scan Options Menu
Power(KDC500 only)
Users may choose to turn the Scan Engine Power on or off. Select between Enable
and Disable.
Scan Angle
(Opticon laser model only)
This option enables the user to configure the laser beam angle to the barcode. There
are two options for scan angle: Wide and Narrow. Wide is 54
o
and Narrow is 27
o
. The
default is wide.
Filter
(Opticon laser model only)
This menu enables the user to change the Filter mode from Normal to High for poor
quality barcodes. The default is Normal.
Timeout
In this menu, you may set the scan timeout. The timeout options are from 500ms up to
10 seconds. The default is 2 seconds.
Minimum Barcode Length
This option enables the user to set a barcode length from 2 characters to 36 characters
(KDC20/100/200/250/270L/270D/350L/410/411/415/470L/470D/500L) or 2 characters
to 48 characters (KDC30/270C/300/350C/420/421/425/450/470C/500C). It is strongly
recommended that you maximize the minimum barcode length setting to prevent
possible errors.
The default minimum barcode length of
KDC20/100/200/250/270L/270D/350L/410/411/415/470L/470D/500L is 4
characters.
The default minimum barcode length of
KDC30/270C/300/350C/420/421/450/470C/500C is as follows:
Minimum (Default)
Maximum (Default)
1D
Symbology
Codabar
2(4)
60(60)
Code 11
1(4)
80(80)
Code 32
-
-
Code 39
0(0)
48(48)
Code 93
0(0)
80(80)
Code 128
0(0)
80(80)
EAN-8
-
-