Specifications
OM-229 158 Page 22
Possible selections Setup 2:
System Lock − Yes/No
Control Mode − Timed / Remote / Manual Command − Power / Voltage / Current
Max KW: 1−35 Degree Units − F / C
Backlight − Yes/No Isolation Detect − Yes/No
Time Resolution − press the Increase   or Decrease   button to select the desired time resolution.
 The factory default is seconds.
KW Second Alarm − press the Increase   or Decrease   button to select the desired KW Second Alarm.
 The factory default is No.
 If KW Second Alarm is enabled, set Minimum and Maximum values.
KW Second Scale − press the Increase   or Decrease   button to select the desired KW Second Scale.
 The factory default is x1.
External Interrupt − press the Increase   or Decrease   button to enable or disable this feature.
 The factory default is Yes.
Remote Enable − press the Increase   or Decrease   button to select a remote command source.
 The factory default is No.
System Lock − press the Increase   or Decrease   button to lock or unlock the operator interface to 
prevent tampering with any programs. Yes indicates the system is locked, and No indicates the system is
unlocked.
 The factory default is No (unlocked).
Control Mode − press the Increase   or Decrease   button to select the desired method of system  control. For more de-
tails about methods of control, see Section 6-4.
 The factory default is time based control.
Command − press the Increase   or Decrease   button to select the desired command mode.
 The factory default is Power.
Max KW − press the Increase   or Decrease   button to adjust the maximum power source output.
 The factory default is 35 kW.
Degree Units − press the Increase   or Decrease   buttons to select temperature units. Selection will  drive the C indicator
LED.
 The factory default is C.