English
Table of Contents 1. Accessories ------------------------------------------------------------------------1 2. Introduction--------------------------------------------------------------------------2 3. Working Principle---------------------------------------------------------------- 3 4. Technical Specification----------------------------------------------------------4 5. Structure----------------------------------------------------------------------------5 6.
Accessories 1 inner air exhaust adaptor -------------------------------------------------------1 pc 2 air exhaust duct ---------------------------------------------- --------------------1 pc 3 adaptor ------------------------------------------------------------------------------1 pc 4 mounting duct ---------------------------------------------------------------------1 pc 5 window kit --------------------------------------------------------------------------1 pc 6 cap cover ----------------------
Introduction This mobile air conditioner is a new generation air conditioner which is ideal for using in bedroom, study room, lobby, office, meeting room, warehouse attics, sports hall and other entertainment room. Its flexibility characteristic enables easy adjustments to desirable room temperature and humidity. Besides, the built-in filter can remove floating dust, purify air to create a healthy working environment.
Working Principle Refrigerant with low temperature and low pressure is compressed by the compressor to high temperature and high pressure vapour, then cools in the condenser (This is a forced air cooling process: room air passes condenser surface, absorbs the refrigerant's heat in the condenser by heat exchange, then the room air warms up and the warm air is exhausted through the air exhaust duct,) to become high pressure liquid.
Technical Specification Unit specifications: Model AC-ZP112 Cooling Capacity ( Btu / h ) 12000 Dehumidifying Capacity ( L / day ) 24 Power consumption( W ) 1200 Flow Volume (m3 / h ) 480 Sound pressure level dB(A) ≤55 Net Weight ( Kg ) 33 Dimension Body ( mm ) 738*446*377 Package ( mm ) 860*460*450 Refrigerant R407C Note: 1. The above cooling capacity measured at ambient temperature Db 27°C/19°C Wb 27°C/19°C.
Structure 1. Control panel 2. Air outlet 3. Handle 4. Caster 5. Air filter 6. Air inlet 7. Exhaust air outlet 8. Cord Hanger 9. Water stopper 5 6 7 8 9 10. Inner air exhaust adaptor-connect with air exhaust duct (11) and exhaust air outlet (7) 11. Air exhaust duct 12. Adaptor 13. Mounting Duct 14. Window kit 15. Water plate 16.
Operation 1. Control panel AC-ZP112 2 5 3 1 4 7 6 2.On/Off switch button Press On/Off button once the power is on, the unit will run at auto mode. Press On/Off button while the unit is running, the unit stops, and timer setting is canceled, other information (mode, set temp, and fan speed) remain in the machine. 3. Mode button Press Mode button, unit run mode will change at sequence of: AUTO, COOL,, DEHUMIDIFY and To should of the LED light is bright. 4.
Operation Remote control: : Please point the controller transmission section to the signal receiver on the unit panel. Indicator lights on the machine control panel can display AUTO, COOLING, FAN, DEHUMIDIFYING, SPEED, TEMPERATURE, TIMER etc information. M ode Button: Press once w ill change the unit run m ode. Fan speed Button: Press once can change fanspeed at sequence of Low ,M id and H igh speed.
Operation Remote control (cooling mode) Setting temperature range 15°C—31°C(60-90°F). When the room temperature sensor’s temperature is higher than the set temperature, the compressor starts to run. When the room temperature sensor’s temperature is lower than the set temperature, the compressor stops and fan operates at original speed. 1. P ress O N /O FF button, the system starts to run. MODE S P EE D + ℃/ ° F S W IN G _ TIM ER 2.P ress Tem p button to set the desired room tem p. 3.
Operation Remote control (dehumidifying mode) Dehumidifying mode: the compressor and lower fan are running and the upper fan is running at low speed. MODE 2.P ress M O D E button to choose D E H U M ID IFY IN G m ode. 1.M ount batteries and press O N /O FF ,the system starts to run. SPEED + ℃/° F S W IN G _ TIM ER Remote control (Timer) MODE SPEED + ℃/ ° F SW ING _ TIMER 1. While the unit is under running, press Timer button to set unit auto OFF time. 2.
Battery Operation Please notice the anode and cathode while mounting the batteries. We suggest using alkaline batteries. If the battery is to be replaced or thrown away, the batteries must be removed and dispose of in accordance with the current laws as it represents an environmental hazard. Remote control inserting the batteries 1. slide the cover as shown in figure. 2. insert two new non-rechargeable batteries, being careful to place them in the correct position(+) and (-). 3.
Operation Air exhaust duct The unit is called mobile air conditioner, it is movable from one room to another conveniently. You can use the following method to exhaust the hot air. 1. exhaust heat from window (see figure A) Open window for a small angle to put bend mounting duct and fit it on the window. ≥ 50cm ≥ A ≥ 50c m ≥ 50c m B 2. exhaust hot air from the door (see figure B) Open door to an appropriate angle to fit air exhaust duct outside.
Operation Window kit installation(Take the example with three parts of tracks.) 1. Loose nut anti clockwise and unscrew such as Fig 1. 2. adjust the washer on board 1 at the sliding groove on board 2, and then insert the fixation board 2 in the fixation board 1 such as fig.2 3. adjust according to own window size and fix nut on the fixation board 1 clockwise such as fig.
Operation Window kit installation Your window kit has been designed to fit most standard “vertical” and “Horizontal” window applications. However, it may be necessary for you to improve/modify some aspects of the installation procedures for certain types of window.(Take the example with three parts of tracks.) Please refer to see the figures for minimum and maximum window openings.
Operation Air exhaust duct connection 1. air exhaust duct can be extended from 0.5 to 1.5 meters, the unit works more efficiently while the air exhaust duct is shorter. 2. please make sure the air exhaust duct is not distorted, or flow back the hot air to increase the temperature of the body. If so, the unit will stop running automatically 3. please make sure not to use other type of air exhaust duct, or over extend the exhaust duct. Otherwise the unit working efficiency will decrease.
Maintenance Turn off the unit before cleaning, make sure all sockets are pulled out. Do not use chemical solvent (like benzene) to clean the unit surface, or the unit surface will be easily scratched, damaged, even casing could be deformed. If the air filter is blocked with dust, the airflow volume will decrease. It is better to clean the filter for every two months Open the air filter Take out the air filter cover from back air inflow vent.
Maintenance Drainage: When unit running in cooling mode, mostly the water can be drained out through the exhausted hose, however, if the environment is too humid, condensed water can not completely be drained out by this way. In this case, we need to drain the water. While water tray is full, error code “E4” will appear in display, meanwhile, the cooling mode will stop running automatically, and fan will stop in 3 minutes accordingly as well.
Maintenance B.Connect drainage 1. disconnect drainage knob and the rubber plug; 2. connect supplied drainage pipe to drainage hole, water will flow out automatically; 3. if you want to extend drainage pipe, you can use 18mm(diameter) plastic pipe and connect with the drainage pipe. R u bber Plu g D rain age K n ob D rain age Pipe E xten d D rain age Pipe (D iam eter:18mm ) D rain age Pipe Important notice 1.
Trouble shooting Before asking for repair, please check: PROBLEMS CAUSES SUGGEST SOLUTIONS Power supply fault: 1. Not plug in; The unit does not 2. Bad plug or socket; 3. Fuse broken or wire work broken; 1. Plug in correctly; 2. Change the plug or the socket; 3. Send the unit to service center to change the fuse ;( fuse: 3.
Safety Cautions 1. Do not use unit near gas appliance, fires or in the vicinity of flammable liquids. 2. Do not let children put their fingers into the air outlet to avoid danger. 3. Do not incline the unit more than 35° while moving the unit. 4. Do not beat or extrude unit to prevent unit broken, do not vibrate the unit. 5. Keep the unit two meters away from TV sets or radios to avoid the risk of electromagnetic interface. 6.
Special Guide Line 1. Do not incline the unit more than 5° degree, if so, please turn off power supply immediately and ask for advice from your local dealer. 2. Do not spray insecticide or other chemicals to avoid deformation of plastic case. 3. The unit, due to its moving feature, it can be moved from room to room and it is different from window type or split type air conditioner. If the unit cannot cool down the room temperature efficiently, it is not the unit’s quality problem.
After Sale Service When there are problems with the unit, please stop using it and ask for help from your local dealer or service center. Maintenance: After running for several seasons, there will be dust covered in the air filter. This will reduce the airflow volume and influence the cooling efficiency of the unit.
Electric Circuit Drawing -22-
Disposal of Used Electrical & Electronic Equipment The meaning of the symbol on the product, its accessory or packaging indicates that this product shall not be treated as household waste. Please, dispose of this equipment at your applicable collection point for the recycling of electrical & electronic equipments waste. In the European Union and Other European countries which there are separate collection systems for used electrical and electronic product.