User guide
Table Of Contents
- warning_page.pdf
- MPC1000
- Table of contents
- Chapter 1 : Introduction
- Chapter 2 : Basic Operation
- Chapter 3 : Sequencer feature
- MAIN page
- Recording the performance
- Playing back a sequence
- Other useful features for recording sequences
- Detailed information on sequence feature
- Setting the length of a sequence
- Setting the time signature of the sequence
- Setting tempo
- Setting the loop for a sequence
- Changing the default settings
- Changing the sequence name
- Changing the default name for a sequence
- Copying a sequence
- Deleting a sequence
- Deleting all sequences
- Handling the duration (the length of a note) at the loop boundary
- Track features
- MIDI sequencer features
- Chapter 4 : Editing sequences
- Chapter 5 : Step editing
- Chapter 6 : Song mode
- Chapter 7 : Functions of a pad
- Chapter 8 : Q-Link slider
- Chapter 9 : Using the MPC1000 with external devices
- Chapter 10 : Recording a sample
- Chapter 11 : Editing a sample
- Chapter 12 : Program
- Creating a program
- Assigning/Reassigning samples to the pads
- Playing the sample while the pad is being hit
- Setting the volume and the tuning for a sample
- Changing the sample volume with velocity
- Playing several samples with one pad
- Switching between samples using velocity
- Setting the envelope for a pad
- The functions in the Program window
- Editing the sound of a sample
- Simulating the open/close hi-hat (setting the mute group)
- Setting the overlap of the sounds on the same pad (voice overlap)
- Delete all the unused samples at the same time (PURGE)
- Setting a MIDI note number to the pads
- Assigning MIDI note numbers to the pads (changing the default setting)
- Chapter 13 : Mixer
- Chapter 14 : Effect
- Chapter 15 : Save / Load
- Chapter 16 : Connecting the MPC1000 to your computer
- Chapter 17 : Other settings
- Appendix

MPC1000 V2 Operator’s Manual Rev 1.0
95
Loading a sequence
You can load a sequence file one by one.
01. Select the sequence file and load it. The Load a Se-
quence window will be displayed.
02. In the Load into field, select the destination sequence
number.
Select the sequence number to load the data to.
03. Press the [F5] (DO IT) key.
The MPC1000 will start loading the data.
Loading the ALL file
You can load the ALL file, which has sequence and song
data. When you load the ALL file, all the sequences
and songs, which are currently in the MPC1000, will
be replaced by the new data.
01. Select the ALL file and load it. The Load ALL
(SEQS&SONGS) File window will be displayed.
02. Press the [F5] (DO IT) key.
The MPC1000 will start loading the data.
Loading an individual sequence from the ALL file
•
You can load an individual sequence from the ALL file
01. Select the ALL file and load it. The Load ALL
(SEQS&SONGS) File window will be displayed.
02. Press the [F3] (SEQ) key.
The Load a Sequence window will be displayed.
03. In the Load file field, select the sequence to load.
In the Load file field, you can select a sequence data
in the ALL file.
04. In the Load into field, select the destination sequence.
Select the sequence number to load the data to.
05. Press the [F5] (DO IT) key.
The MPC1000 will start loading the data.
• Loading only the effect set from the ALL file
The ALL file has effect set file, which has the effect
setting information. You can load only the effect
set from the ALL file.
01. Select the ALL file and load it. Load ALL
(SEQS&SONGS) File window will be displayed.
02. Press the [F2] (EFFECT) key.
The Load Effect File window will be displayed.
03. In the Load file field, select the effect set to load.
04.
In the Load into field, select the destination effect set.
Select the effect set number to load the data to.
If you select ALL in the Load file field, the current
effect set in the unit will be replaced by the data
from the ALL file.
05. Press the [F5] (DO IT) key.
The MPC1000 will start loading the data.
Loading a folder
You can load a folder and load all the files within the
folder at the same time. You can load program, sample,
and ALL files.
01. Select a folder and load it. The Load Folder window
will be displayed.
02.
Make a setting in the Replace same files in memory field.
You can set how to handle the file when you al-
ready have the data with the same name as the load-
ing file in the unit.
NO The MPC1000 will not load the file with
the same name.
YES The MPC1000 will overwrite the data in
the unit by the loaded file.
03. Press the [F5] (DO IT) key.
The loading will begin.
•
Loading the folder after deleting the data
in the memory
When you press the [F2] (CLEAR) key instead of
the [F5] (DO IT) key in step 3, you can clear the
MPC1000’s memory and load the selected folder.
01. In the step 3, press the [F2] (CLEAR) key instead of
the [F5] (DO IT) key.
The CAUTION window will be displayed. If you
press the [F5] (DO IT) key, the MPC1000 will start
loading the folder after it clears all its internal memory.
Note : If you do this operation, all the data saved in the unit will
be deleted.
Note : If the folder has several ALL file, the MPC1000 will load